Variations of Thermal Conductivity of Insulation Materials Under Different Operating Temperatures: Impact on Envelope-Induced Cooling Load
Publication: Journal of Architectural Engineering
Volume 8, Issue 4
Abstract
The thermal and energy performance of buildings depends on the thermal characteristics of the building envelope, and particularly on the thermal resistance of the insulation material used. The performance of the thermal insulation material is mainly determined by its thermal conductivity, which describes the ability of heat to flow across the material in the presence of a differential temperature. The value of the thermal conductivity of a particular material is subject to variation, due to changes in both moisture content and temperature. In reality, thermal insulation in buildings is exposed to significant and continuous temperature variations, due to varying outdoor air temperature and solar radiation. However, when calculating cooling loads or performing energy analyses for buildings, most designers, if not all, use published or manufacturer-supplied values of thermal conductivity, which are normally evaluated at according to the ASTM standards. Currently, many types of insulation materials are produced in Saudi Arabia, but not enough information is available to evaluate their performance under the prevailing climatic conditions. The objective of this paper is to present the results of a study that investigates the relationship between the temperature and thermal conductivity of various types of locally produced insulation materials. Additionally, the impact of thermal conductivity variation with temperature on the envelope-induced cooling load for a theoretically modeled building is quantified and discussed. Results are expected to clarify the issue of thermal conductivity dependence on temperature and lead to a more accurate assessment of the thermal and energy performance of buildings.
Get full access to this article
View all available purchase options and get full access to this article.
References
Abdelrahman, M. A., and Ahmad, A.(1991). “Cost effective use of thermal insulation in hot climates.” Build. Environ., 26(2), 189–194.
Ahmed, A., and Elhadidy, M. A. (2002). “Energy conservation measures for a typical detached single family house in Dhahran.” Proc., 1st Symp. on Energy Conservation and Management in Buildings, King Fahd Univ. of Petroleum and Minerals, Dhahran, Saudi Arabia, 31–42.
Aldrich, D. F., and Bond, R. H. (1985). “Thermal performance of rigid cellular foam insulation at subfreezing temperatures.” Thermal Performance of Exterior Envelopes of Buildings III Conf., American Society of Heating, Refrigerating and Air-Conditioning Engineers/Dept. of Energy/Building Thermal Envelope Coordinating Council, Fla., 500–509.
Al-Hammad, A., Abderrahman, M. A., Grondzik, W., and Hawari, A.(1994). “A comparison between actual and published K-values for Saudi insulation materials.” J. Thermal Insulation and Building Envelope, 17, 378–385.
Al-Homoud, M. S.(1997a). “Optimum thermal design of air-conditioned residential buildings.” Build. Environ., 32(3), 203–210.
Al-Homoud, M. S.(1997b). “Optimum thermal design of office buildings.” Int. J. Energy Res., 21, 941–957.
ASTM. (1991a). “Standard practice for selecting temperatures for evaluating and reporting thermal properties of thermal insulation.” C 1058-92, West Conshohocken, Pa.
ASTM. (1991b). “Standard test method for steady-state heat flux measurements and thermal transmission properties by means of heat flow meter apparatus.” C 518-91, West Conshohocken, Pa.
Besan, R. W., and Miller, E. (1982). “Thermal resistance of loose-fill fiberglass insulation spaces heated from below.” Thermal performance of the exterior envelopes of buildings II, Proc., American Society of Heating, Refrigeration, and Air-Conditioning Engineers/DOE Conf., American Society of Heating, Refrigerating and Air-Conditioning Engineers/U.S. Dept. of Energy, Las Vegas, 720–733.
Electrical Affairs Agency (EAA). (1999). “Electricity growth and development in the kingdom of Saudi Arabia.” Rep., Ministry of Industry and Electricity, Riyadh, Saudi Arabia.
Handbook of fundamentals. (1997). American Society of Heating, Refrigerating and Air-Conditioning Engineers, Atlanta, Chap. 26.47–49.
“Heat flow meter thermal conductivity instrumentation.” (1997). Lambda 2000 series operation manual, Holometrix Inc., Bedford, Mass.
Kochhar, G. S., and Manohar, K. (1995). “Effect of moisture on thermal conductivity of fibers: Biological insulating materials.” Thermal Performance of Exterior Envelopes of Buildings VI Conf., American Society of Heating, Refrigerating and Air-Conditioning Engineers, Fla., 33–40.
Said, S. A., and Abdelrahman, M. A.(1989). “Energy efficiency of a building in the eastern province of Saudi Arabia: Parametric analysis with DOE 2.1A.” American Society of Heating, Refrigeration, and Air-Conditioning Engineers Trans., 95, Part I, 147–152.
Wilkes, K. E., and Child, P. W. (1992). “Thermal performance of Fiberglas and cellulose attic insulation.” Thermal performance of the exterior envelopes of buildings V, American Society of Heating, Refrigeration, and Air-Conditioning Engineers/DOE/BTECC/CIBSE Conf., American Society of Heating, Refrigerating and Air-Conditioning Engineers/ Dept. of Energy/Building Thermal Envelope Coordinating Council/Chartered Institution of Building Services Engineers, Fla., 357–367.
Information & Authors
Information
Published In
Copyright
Copyright © 2002 American Society of Civil Engineers.
History
Received: Mar 27, 2002
Accepted: Jun 10, 2002
Published online: Nov 15, 2002
Published in print: Dec 2002
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.