Tests on Bond of Galvanized Rebar and Concrete Cured in Seawater
Publication: Journal of Materials in Civil Engineering
Volume 13, Issue 5
Abstract
It has been claimed in the past that one of the main concerns regarding the use of galvanized reinforcement is a possible decrease of the rebar/concrete bond strength. The available results in the literature are contradictory to this. Besides, no long-term-study results have been found. In this paper, a series of tests is presented that compares the bond of deformed bare rebars with galvanized ones, exposed up to 10 years to a chloride environment in natural seawater (Mediterranean). In the case of galvanized rebars, the action of an H2 inhibitor has been considered as well. The results show that galvanized rebars maintain bond characteristics throughout the test period, with values much higher than the minimum requirements. The addition of an H2 inhibitor or the use of cements with a high alkali content has shown to be irrelevant in the long term.
Get full access to this article
View all available purchase options and get full access to this article.
References
1.
Arliguie, G., Duval, R., and Longuet, P. ( 1979). “Comportement du zinc dans les pâtes de ciment.” Ciments, Betons, Platres, Chaux, 4/79(719), 201–206.
2.
Bird, C. E. ( 1964). “Influence of minor constituents in portland cement in the behavior of galvanized steel in concrete.” Corrosion Prevention & Control, 11(7), 17.
3.
Cornet, I., and Bresler, B. ( 1966). “Corrosion of steel and galvanized steel in concrete.” Mat. Protection, 69.
4.
De Larrard, F., Schaller, I., and Fuchs, J. ( 1993). “Effect of bar diameter on the bond strength of passive reinforcement in high-performance concrete.” ACI Mat. J., 333–339.
5.
Hofsoy, A., and Gukild, I. ( 1969). “Bond studies on hot dip galvanized reinforcement in concrete.” ACI Mat. J., (March), 174–184.
6.
Jokela, J., Metso, J., and Sarja, A. ( 1982). “Zinc coated concrete reinforcement.” Rep. 13, Nordic Concrete Research, Oslo.
7.
RILEM. ( 1994a). “RC5: Bond test for reinforcement steel. 1. Beam test.” RILEM technical recommendations for the testing and use of construction materials, E & FN Spon, U.K.
8.
RILEM. ( 1994b). “RC6: Bond test for reinforcement steel. 2. Pull-out test.” RILEM technical recommendations for the testing and use of construction materials, E & FN Spon, U.K.
9.
Rodríguez, J., et al. ( 1996). “Assessing structural conditions of concrete structures with corroded reinforcement.” Concrete Repair, Rehabilitation and Protection, Int. Congr. on Concrete in the Service of Mankind, R. K. Dhir and M. R. Jones, eds., E & FN Spon, Dundee, U.K., 65–77.
10.
Rodríguez, J., Ortega, L. M., and Casal, J. ( 1997). “Load carrying capacity of concrete structures with corroded reinforcement.” Int. Conf. on Struct. Faults and Repairs, Construction and Building Materials, Elsevier, London, 11(4), 239–248.
Information & Authors
Information
Published In
History
Received: Nov 5, 1999
Published online: Oct 1, 2001
Published in print: Oct 2001
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.