Flexural Behavior of Slurry Infiltrated Mat Concrete (SIMCON)
Publication: Journal of Materials in Civil Engineering
Volume 9, Issue 4
Abstract
Slurry infiltrated mat concrete (SIMCON) is a new kind of fiber reinforced concrete with fibers preplaced in a mat form. It is shown in this paper that the mechanical properties of SIMCON such as flexural strength and toughness are improved significantly compared with conventional fiber reinforced concrete, due to the high fiber volume fraction and aspect ratio. Twelve series with a total 36 SIMCON specimens were tested under third-point bending. The effects of fiber volume fraction and fiber mat thickness on flexural behavior of SIMCON were studied in this experimental investigation. A special failure mode, consisting of a major vertical crack and horizontal branches, was observed and is analyzed in this paper.
Get full access to this article
View all available purchase options and get full access to this article.
References
1.
Balaguru, P., and Shah, S. (1992). Fiber-reinforced cement composites. McGraw-Hill, Inc., New York, N.Y.
2.
Bayasi, Z. (1989). “Steel fiber reinforced concrete properties and applications,” PhD thesis, Michigan State Univ., East Lansing, Mich.
3.
Bayasi, Z., and Zhou, J. (1992). “Application of steel fiber reinforced concrete in pavements and analysis.”Design and construction of steel fiber reinforced concrete, The Chinese Inst. of Civ. and Hydr. Engrg., Taipei, Taiwan, 203–234.
4.
Bentur, A., and Mindess S. (1990). Fiber reinforced cementitious composites, Elsevier Applied Science, New York, N.Y.
5.
Hackman, L. E., Farrell, M. B., and Dunham, O. O.(1992). “Slurry infiltrated mat concrete (SIMCON).”Concrete Int., 14(12), 52–56.
6.
Hughes, B., and Fattuhi, N.(1977). “Load-deflection curves for fiber reinforced concrete beams in flexure.”Magazine of Concrete Res., 29(101), 199–206.
7.
Josifek, C., and Lankard, D. (1987). “SIFCON: slurry infiltrated fiber concrete.”Proc., Fiber Reinforced Concrete Int. Symp., 7.15–7.23.
8.
Law, V.(1987). “Stress-strain curve of fibrous composites.”J. Mat. Sci. Letters, 6, 675–678.
9.
“Method of test for flexural strength and flexural toughness of fiber reinforced concrete.” (1983). JCI Standards for Test Method of Fiber Reinforced Concrete, Japan Concrete Inst., Japan, 45–51.
10.
Naaman, A., Moavenzadeh, F., and McGarry, F.(1974). “Probabilistic analysis of fiber reinforced concrete.”J. Engrg. Mech., ASCE, 100(2), 397–413.
11.
Naaman, A. (1987). “Advances in high performance fiber reinforced cement composites.”Proc., Concrete Structures for the Future, IABSEE Symposium, 371–376.
12.
Ramakrishnan, V., Brandshang, T., Coyle, W., and Schrader, E.(1980). “A comparative evaluation of concrete reinforced with straight steel fibers and fibers with deformed ends glued into bundles.”ACI Mat. J., 77(3), 135–143.
13.
Schrader, E. K. (1986). “Fiber reinforced concrete pavements and slabs—a state-of-the-art report.”Steel fiber concrete, Elsevier Applied Science Publishers, Ltd., 109–131.
14.
Soroushian, P., and Lee, C.(1990). “Tensile strength of steel fiber reinforced concrete: correlation with some measures of fiber spacing.”ACI Mat. J., 87(6), 547–546.
15.
“State-of-the-art report on fiber reinforced concrete.” (1982). Rep. ACI 544.1R-82, Am. Concrete Inst., Detroit, Mich.
Information & Authors
Information
Published In
Copyright
Copyright © 1997 American Society of Civil Engineers.
History
Published online: Nov 1, 1997
Published in print: Nov 1997
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.