Behavior of Steel Beam to Concrete-Filled Steel Tubular Column Connections after Exposure to Fire
Publication: Journal of Structural Engineering
Volume 133, Issue 6
Abstract
A nonlinear finite-element analysis (FEA) model was developed in this paper based on the elastoplastic finite-element theory to analyze the load versus deformation relation of steel beam to concrete-filled steel tubular column connections. Six tests on steel beam to concrete-filled steel tubular (CFST) column connections using external ring after exposure to the ISO-834 standard fire were used to verify the theoretical model. The test parameters included the column cross-sectional type, the fire duration time, the level of axial load in the column, and the beam-column strength ratio. Each test specimen consisted of a CFST column and two steel beam segments in cruciform arrangement to represent an interior joint in a building. Three of the six composite connection specimens had circular cross sections and three had square cross sections. Five of the test specimens were simultaneously exposed to the standard ISO-834 fire condition. After they had cooled down to room temperature, each was tested under a constant axial load and a cyclically increasing flexural load. This paper presents an analysis of the experimental results to validate the FEA model and to evaluate the influences of different testing parameters on various characteristics of the beam-column connection performance. Comparisons between the predicted results and the experimental results indicate that the FEA model can predict the relations of steel beam to CFST column connections and the column lateral load resistance after fire with reasonable accuracy. Finally, the FEA model was used to make a parametric study of the influence of the various factors on the postfire behaviors of steel beam to CFST column connections.
Get full access to this article
View all available purchase options and get full access to this article.
Acknowledgments
The research reported in the paper was supported by the National Natural Science Foundation of China (No. 50425823), the Start-Up Fund for Outstanding Incoming Researchers Project of Fujian Province, and the Start-Up Fund for Outstanding Incoming Researchers Project of Tsinghua University. These financial supports are highly appreciated.
References
AISC. (2002). Seismic provisions for structural steel buildings, LRFD, AISC, Chicago.
Alostaz, Y. M., and Schneider, S. P. (1996). “Analytical behavior of connections to concrete-filled steel tubes.” J. Constr. Steel Res., 40(2), 95–127.
Applied Technology Council (ATC). (1992). Guidelines for cyclic seismic testing of components of steel structures, ATC, Redwood City, Calif.
Azizinamini, A., and Schneider, S. P. (2004). “Moment connections to circular concrete-filled steel tube columns.” J. Struct. Eng., 130(2), 213–222.
Chen, W. F., Goto, Y., and Liew, J. Y. R. (1996). Stability design of semirigid frames, Wiley, New York.
Falke, J. (1993). “Comparison of simple calculation methods for the fire design of composite columns and beams.” Proc., Engineering Foundation Conf. on Composite Construction in Steel and Concrete II, ASCE, New York, 226–241.
Han, L. H. (2001). “Fire performance of concrete filled steel tubular beam-columns.” J. Constr. Steel Res., 57(6), 695–709.
Han, L. H., and Huo, J. S. (2003). “Concrete-filled Hollow Structural Steel columns after exposure to ISO-834 fire standard.” J. Struct. Eng., 129(1), 68–78.
Han, L. H., Huo, J. S., and Wang, Y. C. (2005). “Compressive and flexural behaviour of concrete filled steel tubes after exposure to standard fire.” J. Constr. Steel Res., 61(7), 882–901.
Han, L. H., and Lin, X. K. (2004). “Tests on cyclic behavior of concrete-filled hollow structural steel columns after exposure to ISO-834 standard fire.” J. Struct. Eng., 130(11), 1807–1819.
Han, L. H., Lu, H., Yao, G. H., and Liao, F. Y. (2006). “Further study on the flexural behaviour of concrete-filled steel tubes.” J. Constr. Steel Res., 62(6), 554–565.
Han, L. H., Xu, L., and Zhao, X. L. (2003a). “Tests and analysis on the temperature field within CFST with or without protection subjected to a standard fire.” Adv. Struct. Eng., 6(2), 121–133.
Han, L. H., and Yang, Y. F. (2005). “Cyclic performance of concrete-filled steel CHS columns under flexural loading.” J. Constr. Steel Res., 61(4), 423–452.
Han, L. H., Yang, Y. F., and Tao, Z. (2003b). “Concrete-filled thin walled steel RHS beam-columns subjected to cyclic loading.” Thin-Walled Struct., 41(9), 801–833.
Han, L. H., Yang, Y. F., and Xu, L. (2003c). “An experimental study and calculation on the fire resistance of concrete-filled SHS and RHS columns.” J. Constr. Steel Res., 59(4), 427–452.
Hass, R. (1991). “On realistic testing of the fire protection technology of steel and cement supports.” Translation BHPR/NL/T/1444, Melbourne, Australia.
Huo, J. S. (2005). “Behaviour of steel beam to concrete-filled steel tubular column connections after exposure to fire.” Doctoral thesis, Fuzhou Univ., Fuzhou, Fujian Province, China (in Chinese).
Huo, J. S., and Han, L. H. (2006). “Hysteretic behaviors of steel beam to concrete-filled steel tubular column connections after exposure to fire.” J. Building Structures, 27(6), 28–38 (in Chinese).
ISO. (1975). “Fire resistance tests-elements of building construction.” International Standard ISO 834, Geneva, Switzerland.
JGJ101-96. (1997). “Specification of testing methods for earthquake resistant building.” Chinese Building Industry Press, Peking, China (in Chinese).
Kim, D. K., Choi, S. M., and Chung, K. S. (2000). “Structural characteristics of CFT columns subjected fire loading and axial force.” Proc., 6th ASCCS Conf., International Association for Steel-Concrete Composite Structures (ASCCS), 271–278.
Klingsch, W. (1985). “New developments in fire resistance of hollow section structures.” Proc., Hollow Structural Sections in Building Construction, ASCE, New York.
Kodur, V. K. R. (1999). “Performance-based fire resistance design of concrete-filled steel columns.” J. Constr. Steel Res., 51(1), 21–26.
Lie, T. T., and Caron, S. E. (1988). “Fire resistance of hollow steel columns filled with siliceous aggregate concrete: Test results.” NRC-CNRC Internal Rep. No. 570, Ottawa, Canada.
Lie, T. T., and Chabot, M. (1992). “Experimental studies on the fire resistance of hollow steel columns filled with plain concrete.” NRC-CNRC Internal Rep. No. 611, Ottawa, Canada.
Lie, T. T., and Stringer, D. C. (1994). “Calculation of the fire resistance of steel hollow structural section columns filled with plain concrete.” Can. J. Civ. Eng., 21(3), 382–385.
Okada, T., Yamaguchi, T., Sakumoto, Y., and Keira, K. (1991). “Load heat tests of full-scale columns of concrete-filled tubular steel structure using fire-resistant steel for buildings.” Proc., 3rd Int. Conf. on Steel-Concrete Composite Structures (I), International Association for Steel-Concrete Composite Structures (ASCCS), 101–106.
O’Meagher, A. J., Bennetts, I. D., Hutchinson, G. L., and Stevens, L. K. (1991). “Modelling of HSS columns filled with concrete in fire.” BHPR/ENG/R/91/031/PS69, Melbourne, Australia.
Schneider, S. P., and Alostaz, Y. M. (1998). “Experimental behavior of connections to concrete-filled steel tubes.” J. Constr. Steel Res., 45(3), 321–352.
Shen, Z. Y., and Dong, B. (1997). “An experimental-based cumulative damage mechanics model of steel under cyclic loading.” Adv. Struct. Eng., 1(1), 39–46.
“Specification of structural earthquake-resistant design.” (2002). China Building Industry Press, Beijing.
Tan, K. H., and Tang, C. Y. (2004). “Interaction model for unprotected concrete filled steel columns under standard fire conditions.” J. Struct. Eng., 130(9), 1405–1413.
Tang, J. R. (1989). Earthquake-resistant design of reinforced concrete frame connection, South-East University Press, Nanjing, Jiangsu Province, China (in Chinese).
Uy, B., and Bradford, M. A. (1995). “Local buckling of cold formed steel in composite structural elements at elevated temperatures.” J. Constr. Steel Res., 34(1), 53–73.
Wang, Y. C. (1999). “The effects of structural continuity on the fire resistance of concrete filled columns in non-sway frames.” J. Constr. Steel Res., 50(2), 177–197.
Yang, Y. B., and Kuo, S. R. (1994). Theory and analysis of nonlinear framed structures, Simon & Schuster, New York.
Information & Authors
Information
Published In
Copyright
© 2007 ASCE.
History
Received: Nov 18, 2005
Accepted: Apr 19, 2006
Published online: Jun 1, 2007
Published in print: Jun 2007
Notes
Note. Associate Editor: Venkatesh Kumar R. Kodur
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.