Earthquake Input Energy to Two Buildings Connected by Viscous Dampers
Publication: Journal of Structural Engineering
Volume 133, Issue 5
Abstract
A frequency-domain method is developed for evaluating the earthquake input energy to two building structures connected by viscous dampers. It is shown that the earthquake input energies to respective building structures and added viscous connecting dampers can be defined as works done by the boundary forces between the subsystems on their corresponding displacements. Fourier and inverse Fourier transformations enable one to transform the earthquake input energy in time domain to that in frequency domain. The earthquake input energy in frequency domain has an advantage that, while the input energy cannot be decomposed into the term for the structural parameters and that for the parameters of input ground motions in the conventional time-domain approach, it is possible in the proposed frequency-domain approach. It is demonstrated that the proposed energy transfer function is very useful for clearer understanding of dependence of energy consumption ratios in respective buildings and connecting viscous dampers on their properties. It is concluded that the total input energy to the overall system including both buildings and connecting viscous dampers is approximately constant regardless of the quantity and location of connecting viscous dampers. This property leads to an advantageous feature that, if the energy consumption in the connecting viscous dampers increases, the input energies to the buildings can be reduced drastically.
Get full access to this article
View all available purchase options and get full access to this article.
Acknowledgments
Part of the present work is supported by the Grant-in-Aid for Scientific Research of Japan Society for the Promotion of Science (Nos. 16560496 and 18360264). This support is greatly appreciated.
References
Akiyama, H. (1985). Earthquake resistant limit-state design for buildings, University of Tokyo Press, Tokyo.
Berg, G. V., and Thomaides, T. T. (1960). “Energy consumption by structures in strong-motion earthquakes.” Proc., 2nd World Conf. on Earthquake Engineering, Tokyo and Kyoto, Japan, 681–696.
Fajfar, P., and Vidic, T. (1994). “Consistent inelastic design spectra: Hysteretic and input energy.” Earthquake Eng. Struct. Dyn., 23(5), 523–537.
Housner, G. W. (1959). “Behavior of structures during earthquakes.” J. Engrg. Mech. Div., 85(4), 109–129.
Housner, G. W., and Jennings, P. C. (1975). “The capacity of extreme earthquake motions to damage structures.” Structural and geotechnical mechanics, A volume honoring N. M. Newmark and W. J. Hall, eds., Prentice-Hall, Englewood Cliffs, N.J., 102–116.
Kuwamura, H., Kirino, Y., and Akiyama, H. (1994). “Prediction of earthquake energy input from smoothed Fourier amplitude spectrum.” Earthquake Eng. Struct. Dyn., 23(10), 1125–1137.
Leger, P., and Dussault, S. (1992). “Seismic-energy dissipation in MDOF structures.” J. Struct. Eng., 118(5), 1251–1269.
Lyon, R. H. (1975). Statistical energy analysis of dynamical systems, The MIT Press, Cambridge, Mass.
Mahin, S. A., and Lin, J. (1983). “Construction of inelastic response spectrum for single-degree-of-freedom system.” Rep. No. UCB/EERC-83/17, Earthquake Engineering Research Center, Univ. of California, Berkeley, Calif.
Ohi, K., Takanashi, K., and Tanaka, H. (1985). “A simple method to estimate the statistical parameters of energy input to structures during earthquakes.” J. Struct. Constr. Eng., 347, 47–55 (in Japanese).
Ordaz, M., Huerta, B., and Reinoso, E. (2003). “Exact computation of input-energy spectra from Fourier amplitude spectra.” Earthquake Eng. Struct. Dyn., 32, 597–605.
Page, C. H. (1952). “Instantaneous power spectra.” J. Appl. Phys., 23(1), 103–106.
Riddell, R., and Garcia, J. E. (2001). “Hysteretic energy spectrum and damage control.” Earthquake Eng. Struct. Dyn., 30(12), 1791–1816.
Takewaki, I. (2004a). “Bound of earthquake input energy.” J. Struct. Eng., 130(9), 1289–1297.
Takewaki, I. (2004b). “Frequency domain modal analysis of earthquake input energy to highly damped passive control structures.” Earthquake Eng. Struct. Dyn., 33(5), 575–590.
Takewaki, I. (2005a). “Bound of earthquake input energy to soil-structure interaction systems.” Soil Dyn. Earthquake Eng., 25(7–10), 741–752.
Takewaki, I. (2005b). “Closure to ‘Bound of earthquake input energy.’” J. Struct. Eng., 131(10), 1643–1644.
Takewaki, I. (2005c). “Frequency domain analysis of earthquake input energy to structure-pile soil systems.” Eng. Struct., 27(4), 549–563.
Takewaki, I., and Fujimoto, H. (2004). “Earthquake input energy to soil-structure interaction systems: A frequency-domain approach.” Adv. Struct. Eng., 7(5), 399–414.
Trifunac, M. D., Hao, T. Y., and Todorovska, M. I. (2001). “On energy flow in earthquake response.” Rep. No. CE 01-03, Univ. of Southern Calif., Los Angeles.
Trombetti, T., and Silvestri, S. (2004). “Added viscous dampers in shear-type structures: The effectiveness of mass proportional damping.” J. Earthquake Eng., 8(2), 275–313.
Uang, C. M., and Bertero, V. V. (1990). “Evaluation of seismic energy in structures.” Earthquake Eng. Struct. Dyn., 19(1), 77–90.
Zahrah, T. F., and Hall, W. J. (1984). “Earthquake energy absorption in SDOF structures.” J. Struct. Eng., 110(8), 1757–1772.
Information & Authors
Information
Published In
Copyright
© 2007 ASCE.
History
Received: Apr 6, 2005
Accepted: Oct 20, 2006
Published online: May 1, 2007
Published in print: May 2007
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.