Strength of Welded Connections in G450 Sheet Steel
Publication: Journal of Structural Engineering
Volume 131, Issue 10
Abstract
G450 steel to AS 1397 is a cold-reduced sheet steel with in-line galvanizing. Its grade is yield and tensile strength. It is widely used in Australia for purlins, and is being used to fabricate lightweight portal frames, often by welding. The effects of welding on G450 sheet steel in the heat affected zone with respect to the connection strength were unknown. In the present work, transverse and longitudinal fillet, and flare-bevel welded connections in 1.5 and G450 steel were tested to failure. The test results are used to check the relevant design rules in the North American Specification for Cold-Formed Steel Structural Members and the Australian/New Zealand Standard for Cold-Formed Steel Structures AS/NZS 4600. It was found that the current design rules are not adequate for certain connection configurations in G450 steel to achieve the target safety index of 3.5. Reduced resistance (capacity) factors are proposed for some connections. It was also found that the current design rule for longitudinal flare-bevel welded connections is unnecessarily conservative. The quality of welded connections in thin sheet steels produced by industry fabricators was investigated. The need to complement the macrotest with the destructive prying test as part of the prequalification procedure for such connections is demonstrated. Part of the results of the present work has recently been incorporated into the North American Specification for Cold-Formed Steel Structural Members with a lowering of the thickness to above which weld throat failure should be checked.
Get full access to this article
View all available purchase options and get full access to this article.
Acknowledgments
The work reported herein was undertaken as part of a Research Project of the Cooperative Research Centre for Welded Structures (CRC-WS). The CRC-WS was established and is supported under the Australian Government’s Cooperative Research Centres Program. The sheet steel materials used in the test specimens were provided by BHP Steel Coated Products, Port Kembla. The writers would like to thank Paul Grace of the Welding Technology Institute of Australia for his expert advice on proper welding procedures, which were performed by Grant Holgate. The WeldPrint monitoring equipment was provided by Steve Simpson of the School of Electrical and Information Engineering at the University of Sydney.
References
American Iron and Steel Institute (AISI). (2001). “Specification for the design of cold-formed steel structural members.” Washington D.C.
American Welding Society (AWS). (1998). “Structural welding code: Sheet steel.” D1.3-98, Miami.
Chen, Y. W., Dunne, D., Norrish, J., and Szalla, J. (1999) “Effect of GMA welding on microstructure and mechanical properties of G550 sheet steel.” Research Rep., Dept. of Materials Engineering, Univ. of Wollongong, Wollongon, Australia.
Cornell, C. A. (1969). “A probability based structural code.” J. Am. Concr. Inst., 66, 974–985.
Ellingwood, B., Galambos, T. V., MacGregor, J. G., and Cornell, C. A. (1980). “Development of a probability based load criterion for American National Standard A58.” A58, National Bureau of Standards, Gaithersburg, Md.
European Committee for Standardisation (CEN). (1993). “Design of steel structures, Part 1.1—General rules and rules for buildings.” Eurocode 3, Brussels, Belgium.
Pekoz, T., and McGuire, W. (1980). “Welding of sheet steel.” Proc., 5th International Specialty Conf. on Cold-Formed Steel Structures, St. Louis, Mo., 637–662.
Ravindra, M. K., and Galambos, T. V. (1978). “Load and resistance factor design for steel.” J. Struct. Div. ASCE, 104, 1337–1353.
Standards Australia (SA). (1993b). “Sheet steel and strip-hot-dipped zinc-coated or aluminium/zinc-coated.” AS 1397-1993, Sydney, Australia.
Standards Australia/Standards New Zealand (SA/SNZ). (1996a). “Cold-formed steel structures.” AS/NZS 4600:1996, Sydney Australia.
Standards Australia/Standards New Zealand (SA/SNZ). (1996b). “Structural plates—Hot-rolled plates and slabs.” AS/NZS 3678:1996, Sydney Australia.
Standards Australia/Standards New Zealand (SA/SNZ). (1996c). “Welding—electrodes—gas metal arc—ferritic steel electrodes.” AS/NZS 2717.1:1996, Sydney, Australia.
Standards Australia/Standards New Zealand (SA/SNZ). (1998). “Cold-formed steel structures—Commentary.” Supplement to AS/NZS 4600:1996, Sydney, Australia.
Standards Australia/Standards New Zealand (SA/SNZ). (2000). “Structural steel welding—Welding of steel structures.” Amendment No. 1 to AS/NZS 1554.1:1995, Sydney, Australia.
Stark, J. W. B., and Soetens, F. (1980). “Welded connections in cold-formed sections.” Proc., 5th International Specialty Conf. on Cold-Formed Steel Structures, St. Louis, 592–636.
Teh, L. H., and Hancock, G. J. (2000). “Strength of fillet welded connections in G450 sheet steels.” Research Rep. No. R802, Dept. of Civil Engineering, Univ. of Sydney, Sydney, Australia.
Teh, L. H., and Hancock, G. J. (2001b) “Strength of flare-bevel and flare-vee welded connections in G450 sheet steels.” Research Rep. No. R806, Dept. of Civil Engineering, Univ. of Sydney, Sydney, Australia.
Wardenier, J., and Koning, C. H. M. (1975a). “Static tension tests on T-joints in structural hollow sections.” Research Rep. No. IBBC-TNO, TH-Delft, The Netherlands.
Wardenier, J., and Koning, C. H. M. (1975b) “Ultimate static strength of welded lattice girder joints in rectangular hollow sections.” Research Rep. No. IBBC-TNO and TH-Delft, The Netherlands.
Welding Technology Institute Pty. Ltd., (2000). WeldPrint, Build 2.70EN, Univ. of Sydney, Sydney, Australia.
Information & Authors
Information
Published In
Copyright
© 2005 ASCE.
History
Received: Jun 25, 2002
Accepted: May 21, 2004
Published online: Oct 1, 2005
Published in print: Oct 2005
Notes
Note. Associate Editor: Mark D. Bowman
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.