Steel Beam-Column Connections Using Shape Memory Alloys
Publication: Journal of Structural Engineering
Volume 130, Issue 5
Abstract
This study evaluates the feasibility of a new class of partially restrained connections using shape memory alloys. In the martensitic form, shape memory alloys (SMAs) have the ability to recover large residual deformations by heating the alloy above its transformation temperature. The proposed connection consists of four large diameter NiTi SMA bars connecting the beam flange to the column flange and serve as the primary moment transfer mechanism. Two full-scale connections were tested using the SAC loading protocol. The connections exhibited a high level of energy dissipation, large ductility capacity, and no strength degradation after being subjected to cycles up to 4% drift. Following the initial testing series, the tendons were heated to recover the residual beam tip displacement. After initiating the shape memory effect within the tendons, the connections were retested, displaying repeatable and stable hysteretic behavior. An additional test was performed under dynamic loading to examine the strain rate effects on the performance of the connection. The dynamic tests showed similar behavior, except for a decrease in energy dissipation capacity when compared to the quasi-static tests.
Get full access to this article
View all available purchase options and get full access to this article.
References
Baz, A., Imam, K., and McCoy, J.(1990). “Active vibration control of flexible beams using shape memory actuators.” J. Sound Vib., 140, 437–456.
Brailovski, V., Trochu, F., and Leboeuf, A. (1997). “Design of shape memory linear actuators.” Proc. SMTS Conf., Asilomar, Calif.
Cardone, D., Dolce, M., and Marnetto, R. (1999). “Devices based on nickel-titanium alloys for the seismic protection of civil structures.” SMST-99 Proc., 1st European Conf. on Shape Memory and Superelastic Technologies, Antwerp Zoo, Belgium.
Croci, G. (2001). “Strengthening of the basilica of St. Francis of Assisi after the September 1997 Earthquake.” Structural Engineering Int.
Delemont, M. (2001). “Seismic retrofit of bridges using shape memory alloys.” MS thesis, School of Civil and Environmental Engineering, Georgia Institute of Technology, Atlanta.
FEMA. (1995). “Steel moment frame structures: Background reports.” FEMA-288, Federal Emergency Management Agency.
Funakubo. (1987). Shape memory alloys, Gordon and Breach, New York.
Higashino, M. (1996). “Experimental and analytical studies of structural control system using shape memory alloy.” 2nd Int. Workshop on Structural Control, 221–232.
Inaudi, J., and Kelly, J. (1994). “Experiments on tuned mass dampers using viscoelastic, frictional and shape memory alloy materials.” Proc., 1st World Conference on Structural Control, 127–136.
Indirli, M., Castellano, M., Clemente, P., and Martelli, A. (2001). “Demo-application of shape memory alloy devices: The rehabilitation of the S. Giorgio Church bell tower.” Proc. SPIE, Smart Structures and Materials.
Krumme, R., Hayes, J., and Sweeney, S. (1995). “Structural damping with shape memory alloys: One class of devices.” Proc. SPIE (The International Society for Optical Engineering), Smart Structures and Materials Conf., Paper No. 2445-21, San Diego.
Leon, R. T. (1995). “Seismic performance of bolted and riveted connections.” FEMA-288, Background Reports: Metallurgy, Fracture Mechanics, Welding, Moment Connections and Frame Systems Behavior.
Lui, Y., Li, Y., Ramesh, K. T., and Van Humbeeck, J.(1999). “High strain rate deformation of martensitic NiTi shape memory alloy.” Scr. Metall., 41(1), 89–95.
Lui, Y., Xie, Z., Van Humbeeck, J., and Delaey, L.(1998). “Asymmetry of stress-strain curves under tension and compression for NiTi shape memory alloys.” Acta Metall.,46(12), 4325–4338.
Lui, Y., Xie, Z., Van Humbeeck, J., and Delaey, L.(1999). “Cyclic deformation of NiTi shape memory alloys.” Mater. Sci. Eng., A, 273–275, 673–678.
MANSIDE (1999). “Memory alloys for new seismic isolation and energy dissipation devices.” Proc. MANSIDE Project, Rome, 1999, 28–29.
Ocel, J. M. (2002). “Cyclic behavior of steel beam-column connections with shape memory alloy connecting elements.” MS Thesis, School of Civil and Environmental Engineering, Georgia Institute of Technology, Atlanta.
Phatouros, C. C., et al. (2000). “Endovascular stenting for carotid artery stenosis: Preliminary experience using the SMA recoverable technology (SMART) stent.” Am. J. Neuroradiol.,21(4), 732–738.
SAC (1997). “Protocol for fabrication, inspection, testing and documentation of beam-column connection test and other experimental specimens.” SAC Rep. SAC/BD-97/02, SAC Joint Venture, Sacramento, Calif.
Smallidge, J. M. (1999). “Behavior of bolted beam-to-column T-stub connections under cyclic loading.” thesis presented to School of Civil and Environmental Engineering, Georgia Institute of Technology, Atlanta.
Soroushian, P., Ostowari, K., Nossoni, A., Chowdgury, H. (2001). “Repair and strengthening of concrete structures through application of corrective post-tensioning forces with shape memory alloys.” Transportation Research Record 1770, Transportation Research Board, Washington, D. C., 20–26.
Swanson, J., and Leon, R.(2001). “Stiffness modeling of bolted T-stub connection components.” J. Struct. Eng., 127(5), 498–505.
Widu, F., Drescher, D., Junker, R., and Bourauel, C.(1999). “Corrosion and biocompatibility of orthodontic wires.” J. Mater. Sci.: Mater. Med., 10(5), 275–281.
Wilde, K., Gardoni, P., and Fujino, Y.(2000). “Base isolation system with shape memory alloy device for elevated highway bridges.” Eng. Struct., 22, 222–229.
Xie, Z., Liu, Y., and Van Humbeeck, J.(1998). “Microstructure of NiTi shape memory alloy due to tension-compression cyclic deformation.” Acta Mater., 46(6), 1989–2000.
Information & Authors
Information
Published In
Copyright
Copyright © 2004 American Society of Civil Engineers.
History
Received: Jul 24, 2002
Accepted: Jun 11, 2003
Published online: Apr 15, 2004
Published in print: May 2004
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.