Inelastic Behavior of Bolted Flange Plate Connections
Publication: Journal of Structural Engineering
Volume 128, Issue 4
Abstract
The inelastic behavior and failure modes of eight full-scale bolted flange plate connections are discussed. This series of tests investigated two modes of behavior: hinging girder and hinging flange plate mechanisms. The tests demonstrated that this connection type induces several mechanisms of stable inelastic behavior including panel zone distortion, bolt-slip, flange plate hinging, and girder hinging beyond the flange plate connection. The failure mode for five of the eight specimens was by ductile tearing of the net girder section beyond the end of the bolted flange plate connection. These were also specimens that experienced a significant amount of girder hinging. Clamp plates added to the end of the flange plate connection prevented net section tearing for at least one specimen and fractured the beam flange and web in the girder hinge region. One specimen failed by fracture of the flange plate in the heat-affected zone of the welded joint. Finally, the specimen that induced significant flange plate hinging failed by fracture across the flange plate.
Get full access to this article
View all available purchase options and get full access to this article.
References
American Institute of Steel Construction (AISC). (1994). Manual of steel construction: load and resistance factor design, 2nd Ed., Vols. 1 and 2, AISC, Chicago.
Chen, W. F., and Patel, K. V. (1971). “Analysis of steel beam-to-column steel connections.” School of Civil Engineering, Rep., Purdue Univ., W. Lafayette, Ind.
Chen, W. F., and Patel, K. V.(1981). “Static behavior of beam-to-column moment connections.” J. Struct. Div. ASCE, ST9, 1815–1839.
Harriott, J. D., and Astaneh-Asl, A. (1990). “Cyclic behavior of steel top and bottom plate moment connections.” Rep. No. UCB/EERC-90/19, Berkeley, Calif.
SAC. (1997). “Protocol for fabrication, inspection, testing, and documentation of beam-column connections tests and other experimental specimens.” SAC Steel Project Rep. No. SAC/BD-97/02, V.1.1, Strategic Air Command, Richmond, Calif.
Schneider, S. P. (2000). “Behavior of bolted flange plate connections.” SAC Rep. No. SAC7.09, Strategic Air Command, Richmond, Calif.
Information & Authors
Information
Published In
Copyright
Copyright © 2002 American Society of Civil Engineers.
History
Received: Nov 7, 2000
Accepted: Jul 23, 2001
Published online: Apr 1, 2002
Published in print: Apr 2002
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.