Net Section Efficiency of Steel Coupons with Power Actuated Fasteners
Publication: Journal of Structural Engineering
Volume 128, Issue 1
Abstract
An experimental investigation was conducted to determine the effect of power actuated fasteners (PAFs) on the net section fracture strength of steel tension members. An extensive series of steel coupons were tested under tension loads. Coupons were provided either with PAFs or with drilled holes with the same diameter as the PAFs. The objective of this study was to determine if current specification rules for computing the net area of tension members with bolt holes could be applied to members with PAFs. The coupons tested with PAFs exhibited consistently higher net section efficiencies than coupons with drilled holes. These results indicate that installing a PAF into a tension member has less effect on the member’s net section fracture strength than a drilled hole. Design recommendations are provided for computing the net area of steel tension members with PAFs.
Get full access to this article
View all available purchase options and get full access to this article.
References
American Institute of Steel Construction (AISC). (1989). Specification for structural steel buildings; allowable stress design and plastic design, Chicago.
American Institute of Steel Construction (AISC). (1993). Load and resistance factor design for structural steel buildings, Chicago.
American National Standards Institute (ANSI). (1995). “American national standard for construction and demolition—powder actuated fastening systems—safety requirements.” A10.3, New York.
ASTM. (1997). “Standard test methods and definitions for mechanical testing of steel products.” A370-97a, West Conshohocken, Pa.
ASTM. (1998). “Standard specification for steel, sheet and strip, high strength, low-alloy, columbium or vanadium, or both, hot-rolled and cold-rolled.” A607-98, West Conshohocken, Pa.
Beck, H. (1997). “Influence of DX-fasteners, drilled holes, self drilling screws and puddle welds on the static stress-strain behavior of structural steel.” Rep. No. A-IF6-9/97, Hilti Corporate Research, Schaan, Liechtenstein.
Ebert, K. A. (1960). “Vorgänge beim einschießen von setzbolzen in stahl.” PhD thesis, Faculty in Mechanical Engineering, Technische Hochschule Carlo-Wilhelmina, Braunschweig, Germany (in German).
European Committee for Standardization. (1991). “Metallic materials: tensile test—Part 1: Test procedure (at room temperature).” EN 10002, Brussels.
European Committee for Standardization. (1992). “Eurocode 3: design of steel structures—Part 1.1: General rules and rules for buildings.” ENV 1993-1-1, Brussels.
European Committee for Standardization. (1994). “Hot-rolled products from non-alloyed structural steels, technical terms of delivery.” EN 10025, Brussels.
Fisher, J. W.(1965). “Behavior of fasteners and plates with holes,” J. Struct. Div. ASCE, 91(ST 6), 265–286.
Galambos, T. V., ed. (1998). “SSRC Technical Memorandum No. 7: Tension testing.” Guide to stability criteria for metal structures, 5th Ed., Wiley, New York.
Gaylord, E., Gaylord, C., and Stallmeyer, J. (1992). Design of steel structures, 3rd Ed., McGraw-Hill, New York.
Glaser, N. J., and Engelhardt, M. D. (1994). “An overview of power driven fastening for steel connections in the U.S. construction industry.” Rep. No. PMFSEL 94-1, Phil M. Ferguson Structural Engineering Laboratory, Univ. of Texas at Austin, Austin, Tex.
Hilti Corporation. (1996). Fastening technology manual—product information (DX), Schaan, Liechtenstein.
Kates, Z., Engelhardt, M. D., and Beck, H. (1999). “Experimental investigation on the effects of power actuated fasteners on open web steel joists.” Rep. No. PMFSEL 99-1, Phil M. Ferguson Structural Engineering Laboratory, Univ. of Texas at Austin, Austin, Tex.
Klee, S., and Seeger, T. (1986). “Interdependendency of system components—powder-actuated tool, fastener and power load—when powder-actuated fastening.” Rep. No. FG-15/1986, Materials Mechanics Division, Darmstadt Technical Univ., Darmstadt, Germany.
Munse, W. H., and Chesson, E.(1963). “Riveted and bolted joints: net section design.” J. Struct. Div. ASCE, 89(ST 1), 107–126.
Powder Actuated Tool Manufacturers’ Institute, Inc. (1991). Powder actuated fastening systems basic training manual, St. Charles, Mo.
Salmon, C., and Johnson, J. (1996). Steel structures; design and behavior, 4th Ed., Harper and Row, New York.
Seeger, T., and Hanel, J.(1975). “Schwingfestigkeitsuntersuchungen an St 52-flachstäben mit setzbolzen für schalldämpfungsmaßnahmen an stahlbrücken mit schienverkehr, teil 2.” Der Stahlbau, 44(3), 85–92 (in German).
Zobel, K. F. (1968). “Untersuchungen über das bolzensetzen in stahl.” PhD thesis, Faculty in Mechanical Engineering, Technische Hochschule Carlo-Wilhelmina, Braunschweig, Germany (in German).
Information & Authors
Information
Published In
Copyright
Copyright © 2002 American Society of Civil Engineers.
History
Accepted: May 22, 2001
Published online: Jan 1, 2002
Published in print: Jan 2002
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.