Consistent Procedure for Creep and Shrinkage Effects in RC Frames
Publication: Journal of Structural Engineering
Volume 127, Issue 7
Abstract
This paper describes a consistent procedure for determining creep and shrinkage effects in RC building frames. The procedure takes into account the sequential nature of application of dead load and the simultaneous nature of application of live load. Shearing action of beams is considered for evaluation of elastic axial forces as well as redistribution of axial forces resulting from creep and shrinkage deformations. In addition to elastic axial forces, the effect of inelastic axial forces on creep deformations, which get generated progressively with time, is also take into account. This procedure overcomes serious shortcomings of the most commonly used procedure, which is recommended to be used for buildings having low beam stiffness. A 60-story example frame is chosen, and results from the proposed procedure are compared with those obtained from the procedure available in the literature. It is shown that errors in the available procedure in differential vertical deflections (between adjacent columns) and column axial forces increase with higher beam stiffness. These errors are quite large even for low beam stiffness values.
Get full access to this article
View all available purchase options and get full access to this article.
References
1.
Banavalkar, P. V., and Wilkerson, S. ( 1993). “Creep and shrinkage of composite columns in tall buildings.” Proc., Symp. on Struct. Engrg. in Natural Hazards Mitigation, ASCE, New York, 1473–1478.
2.
Fintel, M. ( 1974). Handbook of concrete engineering, 2nd Ed., Van Nostrand Reinhold, New York.
3.
Fintel, M., Ghosh, S. K., and Iyengar, H. S. ( 1987). “Column shortening in tall buildings—Prediction and compensation.” Publ. EB108 D, Portland Cement Association, Skokie, Ill., 1–34.
4.
Fintel, M., and Khan, F. R. ( 1969). “Effects of column creep and shrinkage in tall structures—Prediction of inelastic column shortening.” ACI J., 66, 957–967.
5.
Fintel, M., and Khan, F. R. ( 1971). “Effects of column creep and shrinkage in tall structures—Analysis for differential shortening of columns and field observation of structures.” Paper SP 27-4, ACI Spec. Publ. 27, American Concrete Institute, Detroit, 95–119.
6.
Ghosh, S. K. ( 1997). “Differential shortening in tall concrete buildings.” Proc., 15th Struct. Congr., Part I, Vol. 1, ASCE, New York, 135–139.
7.
Pan, L. B., Liu, P. C., and Bakoss, S. L. (1993). “Long term shortening of concrete columns in tall buildings.”J. Struct. Engrg., ASCE, 119(7), 2258–2262.
8.
Smith, B. S., and Coull, A. ( 1991). Tall building structures: Analysis and design, Wiley, New York.
9.
Uy, B., and Das, S. ( 1997). “Time effects in concrete filled steel box columns in tall buildings.” J. Struct. Design of Tall Buildings, 6(1), 1–22.
Information & Authors
Information
Published In
History
Received: Jul 24, 2000
Published online: Jul 1, 2001
Published in print: Jul 2001
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.