Mathematical Model for Relaxation in High-Strength Bolted Connections
Publication: Journal of Structural Engineering
Volume 125, Issue 8
Abstract
High-strength bolted connections with protective coatings are used extensively in bridges. The relaxation in high-strength bolts due to creep in the coating can reduce the shear capacity of the connection. In a recent bridge application using high-strength bolted connections with hot-dip galvanized coating, a loss in the bolt clamping force was observed. Tests have been conducted to evaluate the effect of coating thickness on the bolt clamping force. The reduction in the bolt force for coatings up to 0.508 mm (20 mils) has been shown to be as large as four times that for bare steel. A mathematical model is developed to evaluate the relaxation effect in the high-strength bolted connections. The analytical predictions are compared with experimental data, which shows a very good agreement. An approach is presented to predict the bolt-load retention based on the relevant creep data. The model developed in this paper can also be used for other coating systems to predict the loss of the bolt force due to the creep occurring in the bolted connections.
Get full access to this article
View all available purchase options and get full access to this article.
References
1.
Arimond, J. (1996). “Bolt-load modeling for composites.” Machine Des., 68(12), 114–118.
2.
Bickford, J. H. (1995). An introduction to the design and behavior of bolted joints. 3rd Ed., Marcel Dekker, New York.
3.
DeWolf J. T., and Yang, J. (1998). “Relaxation of high-strength bolted connections with galvanized steel.” Final Rep., Proj. No. 96-4, Conn. Dept. of Transp., Rock Hill, Conn.
4.
Donald, E. (1979). “Bleeding structures—the detection of fatigue in engineering elements.” Aircraft Engrg., Bunhill, London, 51(1), 25–29.
5.
Fisher, J. W., Struik, J. H., and Kulak, G. L. (1974). Guide to design criteria for bolted and riveted joints. Wiley, New York.
6.
Frank, K. H., and Yura, J. A. (1981). “An experimental study of bolted shear connections.” Final Rep., FHWA/RD-81/148, Federal Highway Administration, U.S. Dept. of Transportation, Washington, D.C.
7.
Manual of steel construction—load and resistance factor design, Volume I: Structural members, specifications and codes/Appendix A: Testing method to determine the slip coefficient for coatings used in bolted joints. (1994). 2nd Ed., American Institute of Steel Construction (AISC), Chicago.
8.
Munse, W. H. (1967). “Structural behavior of hot galvanized bolted connections.” Proc., 8th Int. Conf. on Hot-dip Galvanizing, Bb Industrial Newspapers, London.
9.
Nanninga, M. G. ( 1978). “Creep behavior of friction type joints with coated faying surfaces,” MS thesis, University of Texas at Austin, Tex.
10.
Pinney, S. G. (1984). “Painter certification.” J. Prot. Coatings and Linings, 1(6), 112–115.
11.
Sarisley, E. F., and Accorsi, M. (1990). “Prestress level in stresslaminated timber bridges.”J. Struct. Engrg., ASCE, 106(11), 3003– 3019.
12.
Shigley, J. E., and Mischke, C. R. (1989). Mechanical engineering design. 5th Ed., McGraw-Hill, New York.
13.
Specifications for structural joints using ASTM A325 or A490 bolts. (1994). Research Council on Structural Connections, American Institute of Steel Construction, Chicago.
14.
“Standard specification for coatings (hot-dip galvanized) on iron and steel products.” (1989). A123, ASTM, Philadelphia.
15.
Standard specifications for highway bridges. (1992). 15th Ed., American Association of State Highway and Transportation Officials (AASHTO), Washington, D.C.
16.
Webster, J. ( 1994). “Design formula to predict retained steel bolt strength when joining A380 aluminum components at high temperatures.” SAE technical paper 941738, Soc. of Autom. Engrg., Warrendale, Pa.
17.
Yang, J. ( 1997). “Relaxation of high-strength bolted connections with galvanized steel,” MS thesis, University of Connecticut, Storrs, Conn.
18.
Yura, J. A., and Frank, K. H. (1985). “Testing method to determine the slip coefficient for coatings used in bolted joints.” Engrg. J., 3rd Quarter, Am. Inst. of Steel Constr., Chicago, 151–155.
19.
Yura, J. A., Frank, K. H., and Cayes, L. (1981). “Friction-type bolted connections with A588 weathering steel.” Final Rep., No. FHWA/RD-812/147, Federal Highway Administration, U.S. Department of Transportation, Washington, D.C.
Information & Authors
Information
Published In
History
Received: Jul 10, 1998
Published online: Aug 1, 1999
Published in print: Aug 1999
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.