Lateral Resistance of Wood Shear Walls with Large Sheathing Panels
Publication: Journal of Structural Engineering
Volume 123, Issue 12
Abstract
This paper summarizes results from the first phase of a study to evaluate the lateral resistance of wood based shear walls without openings, built with regular and nonstandard large dimension oriented strand board panels under monotonic and cyclic loading conditions. Furthermore, different types and spacings of panel-frame connectors were investigated. Results of the second phase, which considered shear walls with openings, are presented in a subsequent paper. The results of the first phase indicate that under monotonic loading, a substantial increase in both stiffness and lateral load carrying capacity, as well as comparable ductility ratios, can be achieved by shear walls built with oversize panels, compared to regular panels. The walls built with regular panels, however, were found to dissipate more energy under cyclic loading than the walls built with oversize panels. The failure modes were substantially different under monotonic (nail withdrawal) and cyclic (nail fatigue) test conditions, which raised the question as to whether the adopted cyclic loading schedules realistically represent the loading sequence expected under wind and earthquake loading.
Get full access to this article
View all available purchase options and get full access to this article.
References
1.
Adams, N. R. (1987). “Plywood shear walls.”Res. Rep. 105, Am. Plywood Assn., Tacoma, Wash.
2.
ASTM. (1991). “Standard method of static load test for shear resistance of framed walls for buildings.”ASTM E 564-76, ASTM, West Conshohocken, Pa.
3.
Atherton, G. H. (1982). “Ultimate strength of structural waferboard and particleboard diaphragms.” Forest Res. Lab., Oregon State Univ., Corvallis, Oreg.
4.
Atherton, G. H.(1983). “Ultimate strength of particleboard diaphragms.”Forest Products J., 33(5), 22–26.
5.
Boughton, G. N.(1988). “Full-scale structural testing of houses under cyclonic wind loads.”Proc., 1988 Int. Timber Engrg. Conf., Forest Products Res. Soc., Madison, Wis., 2, 82–87.
6.
Canadian Wood Council. (1991). Wood reference handbook. Can. Wood Council, Ottawa, Canada.
7.
COFI. (1979). Douglas-fir plywood diaphragms. Council of Forest Industries of British Columbia, Vancouver, B.C., Canada.
8.
Comite' Europeen de Normalisation (CEN). (1995). “Timber structures—test methods—cyclic testing of joints made with mechanical fasteners.”Draft EN TC 124.117, European Committee for Standardization, Brussels, Belgium.
9.
Dolan, J. D. (1989). “The dynamic response of timber shear walls,” PhD dissertation, Dept. of Civ. Engrg., Univ. of British Columbia, Vancouver, B.C., Canada.
10.
Dolan, J. D.(1994). “Proposed test method for dynamic properties of connections assembled with mechanical fasteners.”J. Testing and Evaluation, 22(6), 542–547.
11.
Ehlbeck, J. (1979). “Nailed joints in wood structures.”Res. Rep. no. 166, Virginia Polytechnic Inst. and State Univ., Blacksburg, Va.
12.
Foliente, G. C., and Zacher, E. G. (1994). “Performance tests of timber structural systems under seismic loads.”Proc., Res. Needs Workshop, Univ. of California, Richmond, Calif., 21–86.
13.
Foschi, R. O.(1974). “Load-slip characteristics of nails.”Wood Sci., 7(1), 69–76.
14.
Gupta, A. K., and Kuo, G. P.(1987). “Modeling of a wood-framed house.”J. Struct. Engrg., ASCE, 113(2), 260–278.
15.
Hunt, R. D., and Bryant, A. H.(1990). “Laterally loaded nail joints in wood.”J. Struct. Engrg., ASCE, 116(1), 111–124.
16.
Kamiya, F.(1988). “Nonlinear earthquake response analysis of sheathed wood walls by a computer actuator on-line system.”Proc., 1988 Int. Timber Engrg. Conf., Forest Products Res. Soc., Madison, Wis., 1, 838–847.
17.
Karacabeyli, E. (1995). “Lateral resistance of nailed shear walls subjected to static and cyclic displacements.”Res. Rep. Presented at FPS 49th Annu. Meeting, Portland, Oreg.
18.
Karacabeyli, E. (1996a). “Joints made with mechanical fasteners.”Meeting Notes of ISO TC 165 (Timber Struct.) Working Group 7 Meeting.
19.
Karacabeyli, E. (1996b). “Quasi-static reversed-cyclic testing of nailed joints.”Proc., Int. Council for Build. Res. Studies and Documentation, Working Commission W18—Timber Struct., Meeting 29, Universität Karlsruhe, Karlsruhe, Germany, 29-7-7.
20.
Kasal, B., and Leichti, R. J.(1992). “Nonlinear finite-element model for light-frame stud walls.”J. Struct. Engrg., ASCE, 118(11), 3122–3135.
21.
Rose, J. D. (1995). “Performance of wood structural panel shear walls under cyclic (reversed) loading.”Res. Rep. Presented at FPS 49th Annu. Meeting, Portland Oreg.
22.
Stewart, A. H., Goodman, J. R., Kliewer, A., and Salsbury, E. M.(1988). “Full-scale tests of manufactured houses under simulated wind loads.”Proc., 1988 Int. Timber Engrg. Conf., Forest Products Res. Soc., Madison, Wis., 2, 97–111.
23.
Stewart, W. G. (1987). “The seismic design of plywood sheathed shearwalls,” PhD dissertation, Dept. of Civ. Engrg., Univ. of Canterbury, Christchurch, New Zealand.
24.
Sugiyama, H., Andoh, N., Uchisako, T., Hirano, S., and Nakamura, N.(1988). “Full-scale test of a Japanese type two-story wooden frame house subjected to lateral load.”Proc., 1988 Int. Timber Engrg. Conf., Forest Products Res. Soc., Madison, Wis., 2, 55–61.
25.
TECO. (1980). “Summary of racking tests conducted on waferboard sheathing.”Rep. Prepared for Can. Waferboard Assn., TECO, Oreg.
26.
TECO. (1981). “Racking load test report on 3 application procedures of 7/16 inch waferboard.”Rep. Prepared for Can. Waferboard Assn., TECO, Oreg.
27.
Tissel, J. R., and Elliott, J. R. (1977). “Plywood diaphragms.”Res. Rep. 138, Am. Plywood Assn., Tacoma, Wash.
28.
Wilkinson, T. L.(1972). “Analysis of nailed joints with dissimilar members.”J. Struct. Engrg., ASCE, 98(9), 2005–2013.
Information & Authors
Information
Published In
Copyright
Copyright © 1997 American Society of Civil Engineers.
History
Published online: Dec 1, 1997
Published in print: Dec 1997
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.