Prying and Shear in End‐Plate Connection Design
Publication: Journal of Structural Engineering
Volume 118, Issue 5
Abstract
Seven large, extended end‐plate connections with eight tension bolts were fabricated and tested to failure at the Fritz Engineering Laboratory. Lehigh University. At least one connection failed by bolt fracture, weld fracture, or plate shear fracture. Experimental results led to concerns for bolt prying forces and end‐plate shear forces. Finite element analysis models, using shell elements for the end plate and beam flanges and plane‐stress elements for the beam web, were developed for the connections. Elastic and inelastic finite element solutions were obtained by using the ADINA program to provide predictions of the magnitude of shear force in the plate projection and the increases in bolt force due to prying action. The analytically predicted bolt forces were compared with the experimentally measured forces and reasonable agreement was found. Simple design rules, which complement the current design procedures for unstiffened end‐plate connections, are presented.
Get full access to this article
View all available purchase options and get full access to this article.
References
1.
A finite element program for automatic dynamic incremental nonlinear analysis.” (1981). Adina Engineering Inc., Watertown, Mass.
2.
Agerskov, H. (1977). “Analysis of bolted connections subject to prying.” J. Struct. Engrg., ASCE, 103(11), 2195–2163.
3.
Allowable stress design manual of steel construction. (1989). American Institute of Steel Construction, Chicago, Ill.
4.
Chasten, C. P. (1988). “Theoretical modeling and testing of 8‐bolt extended end‐plate connections,” Master's thesis, Lehigh University, Bethlehem, Pa.
5.
Chasten, C. P., Fleischman, R. B., Driscoll, G. C., and Lu, L.‐W. (1989). “Top‐and‐seat‐angle connections and end‐plate connections: behavior and strength under monotonic and cyclic loading.” Proc., National Engineering Conf., American Institute of Steel Construction, Chicago, Ill., 6–1–6–32.
6.
Dicorso, P., Harper, W., Reinhorn, A. M., and Dickerson, J. (1989). “Structures with semi‐rigid bolted connections.” Proc. of Structures Congress '89, ASCE, New York, N.Y.
7.
Fisher, J. W., and Struik, J. (1974). Guide to design criteria for bolted and riveted joints. 1st Ed., John Wiley & Sons, Inc., New York, N.Y.
8.
Fleischman, R. B., Chasten, C. P., Lu, L.‐W., and Driscoll, G. C. (1990). “Cyclic behavior of large size flexible beam‐to‐column connections.” Proc., Fourth Nat. Conf. on Earthquake Engineering, University of California, Irvine, Calif., Vol. 2, 687–696.
9.
Fleischman, R. B., Chasten, C. P., Lu, L.‐W., and Driscoll, G. C. (1991). “Top‐and‐seat‐angle connections and end‐plate connections: snug vs. fully pre‐tensioned bolts.” Engrg. J. Am. Inst. Steel Constr., 28(1), 18–28.
10.
Grundy, P., Thomas, I. R., and Bennetts, I. D. (1980). “Beam‐to‐column moment connections.” J. Struct. Engrg., ASCE, 106(1), 313–330.
11.
Kennedy, N. A., Vinnakota, S., and Sherbourne, A. N. (1981). “The split‐tee analogy in bolted splices and beam‐column connections.” Proc. of the Int. Conf. on Joints in Structural Steelwork, Teesside Polytechnic, U.K., 2.138–2.157.
12.
Krishnamurthy, N. (1978). “A fresh look at bolted end‐plate behavior and design.” Engrg. J. Am Inst. Steel Constr., 15(2), 39–49.
13.
Kulak, G. L., Fisher, J. W., and Struik, J. (1987). Guide to design criteria for bolted and riveted joints. 2nd Ed., John Wiley & Sons, Inc., New York, N.Y.
14.
Loads and resistance factor design manual of steel construction. (1986). American Institute of Steel Construction, Chicago, Ill.
15.
Mann, A. P., and Morris, L. J. (1979). “Limit design of extended end‐plate connections.” J. Struct. Engrg., ASCE, 105(3), 511–526.
16.
Manual of steel construction. (1980). American Institute of Steel Construction, Chicago, Ill.
17.
Murray, T. M., and Kukreti, A. R. (1988). “Design of 8‐bolt stiffened moment end plates.” Engrg. J. Am. Inst. Steel Constr., 25(2), 45–52.
18.
Packer, J. A., and Morris, L. J. (1977). “A limit state design method for the tension region of bolted beam‐column connections.” The Struct. Engrg., 55(10), 446–458.
19.
Tsai, K. C., and Popov, E. P. (1990). “Cyclic behavior of end‐plate moment connections.” J. Struct. Engrg., ASCE, 116(11), 2917–2930.