High‐Temperature Properties of Fire‐Resistant Steel for Buildings
Publication: Journal of Structural Engineering
Volume 118, Issue 2
Abstract
This paper presents properties of fire‐resistant (FR) steel for structural use. Because of the elements contained and its rolling process, FR steel retains strength at high temperatures compared with conventional structural steels for buildings. Through mechanical‐properties tests at high temperatures and full‐scale fire tests of load‐bearing members, it is confirmed that FR steel can bear a load corresponding to the allowable stress for structural steel under permanent loading (which is two‐thirds of the room temperature yield point) at 600° C. Also, applications of FR steel to buildings are presented. Through these tests and applications, it is confirmed that FR steel can reduce fire protection compared with conventional structural steels and can also be used in steel buildings without any protection in cases where the steel temperature would not exceed 600° C.
Get full access to this article
View all available purchase options and get full access to this article.
References
1.
Design manual of European recommendations for the fire safety of steel structures. (1985). European Convention for Construction Steelwork (ECCS), Tech. Committee 3, Brussels, Belgium.
2.
Fujimoto, M., Furumura, F., Ave, T., and Shinohara, Y. (1980). “Primary creep of steel (SS41) at high temperatures.” Trans. of Arch. Inst. of Japan, 296, 145–157(in Japanese).
3.
Furumura, F., Ave, T., Okabe, T., and Kim, W. J. (1985). “An experimental formula of stress‐strain relations of structural steels at fire temperature range.” Summaries of Tech. Papers of Annu. Meeting, Arch. Inst. of Japan, Tokyo, Japan, 621–622.
4.
Harada, A., and Furumura, F. (1971). “Studies of mechanical properties of structural steel at high temperatures.” Trans. of Arch. Inst. of Japan, No. 185. 1‐7 (in Japanese).
5.
Harmathy, T. Z., and Stanzak, W. W. (1971). “Elevated‐temperature tensile and creep properties of some structural and prestressing steels.” Special Tech. Publication Number 464, American Society for Testing and Mater. (ASTM), Philadelphia, Pa.
6.
Keira, K., Sakumoto, Y., Yamaguchi, T., and Katashima, A. (1989a). “Studies of structural steels with excellent mechanical properties at elevated temperature, Part 2. Full scale fire tests insulated by mineral fibre.” Summaries of Tech. Papers of Annu. Meeting, Arch. Inst. of Japan, Tokyo, Japan, 1043‐1044 (in Japanese).
7.
Keira, K., Sakumoto, Y., Yamaguchi, T., Ohashi, M., and Yoshida, Y. (1989b). “Studies of structural steels with excellent mechanical properties at elevated temperature, Part 1. Mechanical properties at elevated temperature.” Summaries of Tech. Papers of Annu. Meeting, Arch. Inst. of Japan, Tokyo, Japan, 1041‐1042 (in Japanese).
8.
Law, M. (1978). “Fire safety of external building elements—The design approach.” American Inst. Steel Constr. Engrg. J., 15(2), 59–74.
9.
“Method of high temperature tensile test for steels and heat‐resisting alloys.” (1978). Japanese Industrial Standards Handbook, JIS G0167, Japanese Standards Assoc., Tokyo, Japan, 392–395.
10.
“Method of fire resistance tests for structural parts of buildings.” (1975). Japanese Industrial Standards Handbook, JIS A 1304, Japanese Standards Assoc., Tokyo, Japan, 335–339.
11.
Migita, K., Okabe, T., Furumura, F., Ave, T., and Kim, W. J. (1988). “Elastoplastic creep thermal deformation behavior of multi‐story steel frames designed by the plastic method.” Fire Safety Sci. Proc. Second Int. Symp., Int. Assoc. for Fire Safety, Gaithersburg, Md., 739–748.
12.
“Rolled steels for welded structures.” (1988). Japanese Industrial Standards Handbook, JIS G 3106, Japanese Standards Assoc., Tokyo, Japan, 511–527.
13.
Ryan, J. V., and Robertson, A. F. (1959). “Proposed criteria for defining load failure of beams, floors, and roof constructions during fire tests.” J. Res. Nat. Bur. Stand., 63C, (2), 121–124.
14.
“Standard practice for elevated temperature tensile tests of metallic materials.” (1988). E21‐79, ASTM, Philadelphia, Pa., 190–196.
15.
“Standard methods for fire tests of building construction and materials.” (1983). E119‐83, ASTM, Philadelphia, Pa., 366–392.
16.
The building standard, law of Japan. (1990). The Building Center of Japan, Tokyo, Japan.
17.
Supplement: Mechanical properties of structural steel at high temperature and after being heated. (1968). Japan Society of Steel Construction, 4(33), 5–174 (in Japanese).
18.
Suzuki, H. (1982). “Carbon equivalent for steel weldability.” Document IX‐1230‐82, Int. Inst. of Welding, Cambridge, U.K.
19.
“Testing Method of maximum hardness in weld heat‐affected zone.” (1990). Japanese Industrial Standards Handbook, JIS 8 3101, Japanese Standards Assoc., Tokyo, Japan, 215–216.
20.
Wakamatsu, T. (1988). “Development of design system for building fire safety.” Fire Safety Sci., Proc. Second Int. Symp., Int. Assoc. for Fire Safety, Gaithersburg, Md., 881–895.
Information & Authors
Information
Published In
Copyright
Copyright © 1992 ASCE.
History
Published online: Feb 1, 1992
Published in print: Feb 1992
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.