Modified Stub‐Girder Floor System: Full‐Scale Tests
Publication: Journal of Structural Engineering
Volume 118, Issue 11
Abstract
This paper summarizes the results of load tests on two full‐size stub‐girders. The first, specimen M‐1, had a conventional girder‐to‐column connection and the second, specimen M‐2, featured a modified connection in which an extended end stub was connected to the column support. The modified end details offer some economic advantages, greater convenience for the erection and for installation of services. The test specimens were designed as spandrel stub girders for a typical office floor loading and consisted of three continuous spans. The concrete slab was continuous over the end supports of the interior span. The test results indicated that the stub girder with the modified end details is structurally as efficient as the conventional system. Specimen M‐1 failed by shear yielding of the steel girder, while specimen M‐2 failed by crushing of the concrete slab. The measured ultimate loads were 1.58 and 1.81 times the design factored load for specimens M‐1 and M‐2, respectively. Specimen M‐2, with the modified girder‐to‐column connection, exhibited a 14% increase in the observed ultimate strength over specimen M‐1.
Get full access to this article
View all available purchase options and get full access to this article.
References
1.
Ahmad, M., and Hosain, M. U. (1990). “Stub‐girder floor systems: Full size tests.” Research Report No. 33, Univ. of Saskatchewan, Saskatoon, Canada.
2.
Ahmad, M., and Hosain, M. U. (1991). “Recent research on stub‐girder floor systems.” Proc. of the Int. Conf. on Steel and Aluminium Structures, ICSAS 91, Elsevier Appl. Sci., London, England, 123–132.
3.
Bjorhovde, R., and Zimmerman, T. J. (1980). “Some aspects of stub‐girder design.” Engrg. J. Am. Inst. Steel Constr., 17(3), 54–69.
4.
Chien, E. Y. L., and Ritchie, J. K. (1984). Design and construction of composite floor systems. Canadian Inst. of Steel Constr. (CISC), Willowdale, Ontario, Canada.
5.
Colaco, J. P. (1972). “A stub‐girder system for high‐rise buildings.” Engrg. J. Am. Inst. Steel Constr., 9(3), 89–95.
6.
“Design of concrete structures for buildings.” (1984). CAN3‐A23‐M84, Canadian Standard Association (CSA), Rexdale, Ontario, Canada.
7.
Hosain, M. U., and Tse, W. C. (1984). “Failure mechanisms of stub‐girders.” Proc. of 5th ASCE EMD Specialty Conf., ASCE, New York, N.Y., 595–598.
8.
Kullman, R. B., and Hosain, M. U. (1985). “Shear capacity of stub‐girders: Full‐scale tests.” J. Struct. Engrg., ASCE, 111(1), 56–75.
9.
Lee, L. H., and Park, S. M. (1987). “Strength and deformation of stub‐girder system.” Proc. of the US‐Korea Joint Seminar/Workshop on Critical Engineering System, Seoul, Korea, 561–576.
10.
McConnel, R. E., and Walker, H. B. (1986). “Preliminary report on an ultimate load test of a full scale stub girder floor beam.” Proc. of the Pacific Structural Steel Conf., 187–192.
11.
“Steel structures for buildings (limit states design).” (1984). CAN3‐S16.1‐M84, Canadian Standard Association (CSA), Rexdale, Ontario, Canada.
12.
“Structural quality steels.” (1987). CAN/CSA‐G40.21‐M87, Canadian Standard Association (CSA), Rexdale, Ontario, Canada.
13.
Yarimci, E., Yura, J. A., and Lu, L. W. (1966). “Techniques for testing structures permitted to sway.” Fritz Laboratory Report No. 273.40, Lehigh Univ., Bethlehem, Pa.
Information & Authors
Information
Published In
Copyright
Copyright © 1992 ASCE.
History
Published online: Nov 1, 1992
Published in print: Nov 1992
Authors
Metrics & Citations
Metrics
Citations
Download citation