Seismic Behavior of Gable Frame Consisting of Tapered Members
Publication: Journal of Structural Engineering
Volume 117, Issue 3
Abstract
This paper reports the dynamic responses of a one‐fifth‐scale gable‐frame structure composed of tapered members subjected to El Centro earthquake ground motions, using a shaking table. The test structure was designed according to the American Institute of Steel Construction (AISC) working stress design method. The width‐thickness ratio of the flange and the depth‐thickness ratio of the web of the members satisfy the requirements of a compact section. The unbraced length also meets the criteria for a compact section based on the dimensions of the shallow‐end cross section. Failure of the test structure is due to lateral buckling of rafters. No local buckling prior to the lateral buckling is observed. The experimentally determined ultimate strength of the test structure is compared with those predicted by the codes AISC load and resistance factor design (LRFD), AS 1250, and BS 5950. The experimental results are also compared with those of a similarly designed gable frame composed of prismatic members, tested under similar conditions.
Get full access to this article
View all available purchase options and get full access to this article.
References
1.
Amirikian, A. (1952). “Wedge‐beam framing.” Trans., ASCE, 117, 596.
2.
“Draft limit state steel structures code.” (1987). AS 1250, Standards Assoc. of Australia, Sydney, Australia.
3.
Draft standard specification for the structural use of steelwork in building, part 1: Simple construction and continuous construction. (1977). British Standards Inst., London, England.
4.
Hwang, J. S., Chang, K. C., Lee, G. C., and Ketter, R. L. (1989). “Shaking table tests of a pinned‐base steel gable frame.” J. Struct. Engrg., ASCE, 115(12), 3031–3043.
5.
Lee, G. C., and Ketter, R. L. (1972). “Residual stress in welded tapered shapes.” Civil Engineering Research Report, State Univ. of New York at Buffalo, Buffalo, N.Y.
6.
Lee, G. C., Ketter, R. L., and Hsu, T. L. (1981). Design of single story rigid frames. Metal Building Manufacturers Assoc., Cleveland, Ohio.
7.
Lee, G. C., Morrel, M. L., and Ketter, R. L. (1972). “Design of tapered member.” WRC Bulletin No. 173, Water Res. Council, New York, N.Y.
8.
Load and resistance factor design (LRFD). (1986). 1st Ed., Am. Inst. of Steel Constr., Chicago, Ill.
9.
Manual of steel construction. (1980). 8th Ed., Am. Inst. of Steel Constr., Chicago, Ill.
10.
Morrell, M. L., and Lee, G. C. (1974). “Allowable stress for web‐tapered beams with lateral restraints.” WRC Bulletin 192, Welding Res. Council, New York, N.Y.
11.
Prawel, S. P., Morrel, M. L., and Lee, G. C. (1974). “Bending and buckling strength of tapered structural members.” Welding J., 53(2), 75–84.
12.
Salter, J. B., Anderson, D., and May, I. M. (1980). “Tests on tapered steel column.” The Struct. Engr., 58A(6), 189–193.
13.
Shiomi, H., and Kurata, M. (1984). “Strength formula for tapered beam‐columns.” J. Struct. Engrg., ASCE, 110(7), 1630–1643.
14.
“Structural use of steelwork in buildings.” (1985). BS 5950: Part I, British Standards Inst., London, England.
15.
Tentative provisions for the development of seismic regulation for building. (1978). Appl. Tech. Council, U.S. Nat. Bureau of Standards, Washington, D.C.
16.
Uniform building code. (1982). Int. Conf. of Building Officials, Whittier, Calif.
Information & Authors
Information
Published In
Copyright
Copyright © 1991 ASCE.
History
Published online: Mar 1, 1991
Published in print: Mar 1991