Adjusted Factor Ga for Pipelines with Multiple Outlets and Outflow
Publication: Journal of Irrigation and Drainage Engineering
Volume 125, Issue 6
Abstract
The adjusted factor Ga is a generic friction loss correction factor for pipelines with multiple outlets. The adjusted factor Ga can be applied to pipelines with or without outflow at the downstream end. Furthermore, this factor can be applied to a pipeline where the first outlet is at a full outlet spacing or a fractional outlet spacing from the pipeline inlet. When the outflow at the downstream end is reduced to zero, the adjusted factor Ga reduces to the adjusted factor Fa. If the first outlet is positioned one outlet spacing from the pipeline inlet, the factor Ga reduces to G. Finally, if both the outflow is zero and the first outlet is one outlet spacing from the pipeline inlet, the adjusted factor Ga reduces to a close approximation of the well-known factor F. The adjusted factor Ga is a function of the number of outlets along the pipeline, the location of the first outlet from the pipeline inlet, the outflow ratio, and the velocity exponent of the head loss formula.
Get full access to this article
View all available purchase options and get full access to this article.
References
1.
Anwar, A. A. (1999). “Factor G for pipelines with equally spaced multiple outlets and outflow.”J. Irrig. and Drain. Engrg., ASCE, 125(1), 34–38.
2.
Christiansen, J. E. ( 1942). “Irrigation by sprinkling.” California Agric. Experiment Station Bull. No. 670, University of California, Davis, Calif.
3.
Chu, S. T. (1978). “Modified F factor for irrigation laterals.” Trans. ASAE, 21(1), 116–118.
4.
Churchill, S. W. (1977). “Friction-factor equation spans all fluid-flow regimes.” Chem. Engrg., 84(24), 91–92.
5.
Jensen, M. C., and Fratini, A. M. (1957). “Adjusted `F' factors for sprinkler lateral design.” Agric. Engrg., 38(4), 247.
6.
Keller, J., and Bliesner, R. D. (1990). Sprinkle and trickle irrigation. Chapman & Hall, New York.
7.
Pair, C. H., Hinz, W. W., Reid, C., and Frost, K. R., eds. (1975). Irrigation, 5th Ed., Irrigation Association, Fairfax, Va.
8.
Scaloppi, E. J. (1988). “Adjusted `F' factor for multiple-outlet pipes.”J. Irrig. and Drain. Engrg., ASCE, 114(1), 169–174.
9.
Scaloppi, E. J., and Allen, R. G. (1993). “Hydraulics of irrigation laterals: Comparative analysis.”J. Irrig. and Drain. Engrg., ASCE, 119(1), 91–115.
10.
Smith, R. J. (1990). “Discussion of `Adjusted F factor for multiple-outlet pipes,' by E. J. Scaloppi.”J. Irrig. and Drain. Engrg., ASCE, 116(1), 134–136.
11.
Spiegel, M. R. (1968). Mathematical handbook of formulas and tables. McGraw-Hill, New York.
Information & Authors
Information
Published In
History
Received: Nov 16, 1998
Published online: Dec 1, 1999
Published in print: Dec 1999
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.