Extensive Development of Leak Detection Algorithm by Impulse Response Method
Publication: Journal of Hydraulic Engineering
Volume 131, Issue 3
Abstract
The oscillatory flows in pipeline systems due to excitation by valve operation are efficiently analyzed by the impulse response method. The impact of leakage is incorporated into the transfer functions of the complex head and discharge. Frequency-dependent friction is used to consider the impact of unsteady friction for laminar condition. Extensive development of the impulse response method was made by considering the sources of friction associated with the local and convective acceleration of velocity for turbulent flow. The genetic algorithm was integrated into the impulse response method to calibrate the location and the quantity of leakage. The calibration function for leakage detection can be made using the pressure-head response at the valve, or the pressure-head and flow response at the section upstream from the valve. The proposed leak detection algorithm shows the potentials for being applied to a simple pipeline system with a single leak or multiple leaks.
Get full access to this article
View all available purchase options and get full access to this article.
Acknowledgments
The writer expresses thanks to Dr. Anton Bergant from Slovenia for his permission to use the experimental data from the University of Adelaide. The discussions of unsteady friction with Dr. Didia Covas and Dr. Ivan Stoianov from the Imperial College are gratefully acknowledged.
References
Bergant, A., Simpson, A. R., and Vutkovsky, J. (2001). “Developments in unsteady pipe flow friction modeling.” J. Hydraul. Res., 39(3), 249–257.
Brown, F. T. (1962). “The transient response of fluid lines.” J. Basic Eng., 84(4), 547–553.
Brunone, B., Ferrante, M., and Calabresi, F. (2002). “Discussion of evaluation of unsteady flow resistances by quasi-2D or 1D models by Giuseppe Pezzinga.” J. Hydraul. Eng., 128(6), 646–647.
Brunone, B., Golia, U. M., and Greco, M. (1991). “Some remarks on the momentum equation for fast transients.” Proc., 9th Int. Conf. on Hydraulic Transients with Water Column Separation, Valencia, Italy, 201–298.
Brunone, B., Golia, U. M., and Greco, M. (1995). “Effects of two-dimensionality on pipe transients modeling.” J. Hydraul. Eng., 121(12), 906–912.
Carroll, D. L. (2001). “FORTRAN genetic algorithm (GA) driver.” ⟨http:∕∕cuaerospace.com∕carroll∕ga.html⟩ (May 5, 2002).
Covas, D., Stoianov, I., Graham, N., Maksimovic, C., Ramos, H., and Butler, D. (2002). “Hydraulic transients in polyethylene pipes.” Proc., 2002 Conf. EWRI (CD-Rom), ASCE, Roanoke, Va.
Ghidaoui, M. S., Karney, B. W., and McInnis, D. A. (1998). “Energy estimates for discretization errors in water hammer problems.” J. Hydraul. Eng., 124(4), 384–393.
Goldberg, D. E. (1989). Genetic algorithms in search, optimization and machine learning, Addison-Wesley, Reading, Mass.
Holmboe, E. L., and Rouleau, W. T. (1967). “The effect of viscous shear on transients in liquid lines.” J. Basic Eng., 89(1), 174–180.
Lee, P. J., Vitkovsky, J. P., Lambert, M. F., Simpson, A. R., and Liggett, J. A. (2003). “Frequency response coding for the location of leaks in single pipeline system.” Proc., Int. Conf. Pumps, Electrical Development Systems Applied Urban Water Management (CD-Rom), IAHR and IHR, Valencia, Spain.
Liggett, J. A., and Chen, L. (1994). “Inverse transient analysis in pipe networks.” J. Hydraul. Eng., 120(8), 934–955.
Mpesha, W., Chaudhry, M. H., and Gassman, S. L. (2002). “Leak detection in pipes by frequency response method using a step excitation.” J. Hydraul. Res., 40(1), 55–62.
Mpesha, W., Gassman, S. L., and Chaudhry, M. H. (2001). “Leak detection in pipes by frequency response method.” J. Hydraul. Eng., 127(2), 134–147.
Nash, G. A., and Karney, B. W. (1999). “Efficient inverse transient analysis in series pipe systems.” J. Hydraul. Eng., 125(7), 761–764.
Pezzinga, G. (2002). “Closure to ‘Evaluation of unsteady flow resistances by quasi-2D or 1D models’ by Giuseppe Pezzinga.” J. Hydraul. Eng., 128(6), 647–648.
Roberson, J. A., Cassidy, J. J., and Chaudhry, M. H. (1995). Hydraulic engineering, Wiley, New York.
Simpson, A. R., and Goldberg, D. E. (1994). “Pipeline optimization via genetic algorithms: From theory to practice.” Proc., 2nd Int. Conf. on Water Pipeline Systems, Edinburgh, Scotland, 309–320.
Suo, L., and Wylie, E. B. (1989). “Impulse response method for frequency-dependent pipeline transients.” J. Fluids Eng., 111(4), 478–483.
Suo, L., and Wylie, E. B. (1990). “Complex wavespeed and hydraulic transients in viscoelastic pipes.” Trans. ASME, 112, 496–500.
Vitkovsky, J. P., and Simpson, A. R. (1997). “Calibration and leak detection in pipe networks using inverse transient analysis and genetic algorithms.” Research Rep. No. R 157, Dept. of Civil and Environmental Engineering, The Univ. of Adelaide, Adelaide, Australia, 30–53.
Vitkovsky, J. P., Simpson, A. R., and Lambert, M. F. (2000). “Leak detection and calibration using transients and genetic algorithms.” J. Water Resour. Plan. Manage., 126(4), 262–265.
Wang, X., Lambert, M. F., Simpson, A. R., Liggett, J. A., and Vitkovsky, J. P. (2002). “Leak detection in pipelines using the damping of fluid transients.” J. Hydraul. Eng., 128(7), 697–711.
Wylie, E. B., and Streeter, V. L. (1993). Fluid transient in systems, Prentice Hall, Englewood Cliffs, N.J.
Zhao, M., and Ghidaoui, M. S. (2003). “Efficient quasi-two-dimensional model for water hammer problems.” J. Hydraul. Eng., 129(12), 1007–1013.
Zhao, M., Ghidaoui, M. S. (2004). “Godunov-type solutions for water hammer flows.” J. Hydraul. Eng., 130(4), 341–348.
Zielke, W. (1968). “Frequency-dependent friction in transient pipe flow.” J. Basic Eng., 90(1), 109–115.
Information & Authors
Information
Published In
Copyright
© 2004 ASCE.
History
Received: Apr 26, 2002
Accepted: Jul 21, 2004
Published online: Mar 1, 2005
Published in print: Mar 2005
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.