Geothermal Heat Pumps
Publication: Journal of Energy Engineering
Volume 133, Issue 1
Abstract
Geothermal heat pumps can be considered a sustainable technology, as they reclaim and recycle thermal energy from the earth. In climates with a near balance in the annual heating and cooling loads, they function essentially as a seasonal energy storage scheme. This paper presents an overview of the technology. The various types of geothermal heat pumps are explained along with their relative merits. Detailed discussion is included on the most common method of ground coupling for commercial scale applications, the vertical borehole heat exchanger. Issues with sizing the heat exchanger and grouting it are discussed, as well as the motivation for in situ thermal properties testing. In-building equipment, including the heat pumps themselves, is briefly described. Experience with geothermal heat pumps to date is presented for both residential and commercial scale applications. Regional market penetration and competitiveness are also discussed for both residential and commercial scale applications. The paper concludes that the overall outlook for expanded application of geothermal heat pumps is very favorable.
Get full access to this article
View all available purchase options and get full access to this article.
References
Allan, M. L., and Kavanaugh, S. P. (1999). “Thermal conductivities of cementitious grouts and impact on heat exchanger length design for ground source heat pumps.” HVAC&R Res., 5(2), 85–96.
American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE). (1997). Ground source heat pumps—Design of geothermal systems for commercial and institutional buildings, Atlanta.
American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE). (1998). Operating experiences with commercial ground-source heat pump systems, Atlanta.
American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE). (2000). 2000 ASHRAE handbook, systems and equipment, Atlanta, 8.16–8.20.
American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE). (2003a). 2003 ASHRAE handbook, HVAC applications, Atlanta, 36.3.
American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE). (2003b). 2003 ASHRAE handbook, HVAC applications, Atlanta, 32.11–32.27.
Dept. of the Army. (1978). “Engineering weather data.” Technical Manual No. TM 5-785, Washington, D.C.
Eliadis, T. (2002). “Deep lake water cooling project unveiled in Toronto: Robert F. Kennedy Jr. lends support.” Dist. Energy, 88(3), 18–22.
Heinonen, E. W., Tapscott, R. E., Wildin, M. W., and Beall, A. N. (1997). “Assessment of antifreeze solutions for ground-source heat pump systems.” Rep. No. 908RP, American Society of Heating, Refrigerating, and Air-Conditioning Engineers, Atlanta.
Henderson, H. I. (1999). “Implications of measured commercial building loads on geothermal systems sizing.” Transactions of the American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE), Vol. 105, Paper No. SE-99-20-02.
Kavanaugh, S. P. (1998). “A design method for hybrid ground-source heat pumps.” Transactions of the American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE), Vol. 104, Paper No. TO-98-7-3.
Kavanaugh, S. P. (2000). “Investigation of methods for determining soil and rock formation thermal properties from short-term field tests.” ASHRAE Research Project No. 1118-TRP Final Rep., American Society of Heating, Refrigerating, and Air-Conditioning Engineers, Atlanta.
Kavanaugh, S. P. (2003). “Development of guidelines for the selection and design of the pumping/piping subsystem for ground-coupled heat pump systems.” ASHRAE Research Project No. 1217-TRP Final Rep., American Society of Heating, Refrigerating, and Air-Conditioning Engineers, Atlanta.
Oak Ridge National Laboratory. (Undated). Big savings from the world’s largest installation of geothermal heat pumps, Oak Ridge National Laboratory, Oak Ridge, Tenn.
Phetteplace, G. (2002). “Vertical ground-coupled heat exchanger test requirements.” ERDC/CRREL Letter Rep. No. LR-02-66, Cold Regions Research and Engineering Laboratory, Hanover, N.H.
Phetteplace, G., and Sullivan, W. (1998). “Performance of a hybrid ground-coupled heat pump system.” Transactions of the American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE), Vol. 104, Paper No. SF-98-1-1.
Phetteplace, G., Ueda, H., and Carbee, D. (1992). “Performance of ground-coupled heat pumps in military family housing units.” Proc., 1992 ASME Int. Solar Energy Conference, Maui, Hawaii, 377–383.
Podobnik, J. C., and Horst, B. I. (1998). “A survey of sites using pump and treat remediation methods and a survey study of applying geothermal heat pump systems to pump and treat sites at Lawrence Livermore National Laboratory.” Lawrence Livermore National Laboratory Rep. No. UCRL-ID-132845, Livermore, Calif.
Remund, C. P. (1997). “Grouting for vertical geothermal heat pump systems: Engineering design and field procedures manual.” EPRI Final Rep. No. TR-109169, Electric Power Research Institute, Palo Alto, Calif.
Reynolds, W. C., and Perkins, H. C. (1977). Engineering thermodynamics, McGraw-Hill, New York, 287–289.
Sachs, H. M., and Dinse, D. R. (2000). “Geology and the ground heat exchanger: What engineers need to know.” Proc., American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE), Vol. 106, Atlanta.
Sanner, B., Phetteplace, G., and Hellström, G. (1999). “Introduction to computer models for geothermal heat pumps.” Presented at the International Geothermal Days, Klamath Falls, Ore.
Shonder, J. A., Baxter, V., Hughes, P., and Thornton, J. (2000a). “A comparison of vertical ground heat exchanger design software for commercial applications.” Proc., American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE), Vol. 106, Atlanta.
Shonder, J. A., Baxter, V., Thornton, J., and Hughes, P. (1999a). “A new comparison of vertical ground heat exchanger sizing methods for residential applications.” Proc., American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE), Vol. 105, Atlanta.
Shonder, J. A., Martin, M. A., McLain, H. A., and Hughes, P. J. (2000b). “Comparative analysis of life cycle costs of geothermal heat pumps and three conventional HVAC alternatives.” Proc., American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE), Vol. 106, Atlanta.
Shonder, J. A., Martin, M. A., Sharp, T. R., Durfee, D. J., and Hughes, P. J. (1999b). “Benchmark for performance: Geothermal applications in Lincoln public schools.” Proc., American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE), Vol. 105, Atlanta.
Spilker, E. H. (1998). “Ground-coupled heat pump loop design using thermal conductivity testing and the effect of different backfill materials on vertical bore length.” Proc., American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE), 104, Atlanta.
Thornton, J. W., McDowell, T. P., and Hughes, P. J. (1997). “Comparison of practical vertical ground heat exchanger sizing methods to a Fort Polk data/model benchmark.” Proc., American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE), Vol. 103(2), Atlanta.
Information & Authors
Information
Published In
Copyright
© 2007 ASCE.
History
Received: Sep 7, 2005
Accepted: Sep 7, 2005
Published online: Mar 1, 2007
Published in print: Mar 2007
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.