Economic Dispatch for Flue Gas Desulfurization
Publication: Journal of Energy Engineering
Volume 109, Issue 1
Abstract
An economic dispatch model is developed to simulate the daily load dispatch operations of a power system. The model has been used to account for the operation of various flue gas desulfurization (FGD) systems and their impacts on power system economic dispatch pattern and emissions. Simulations performed on a hypothetical test power system with nine coal‐fired generating units showed that the lime and the Wellman‐Lord processes are the two least costly FGD systems to operate. The limestone process is also competitive. The same three processes are also found to be the most cost‐effective FGD systems.
Get full access to this article
View all available purchase options and get full access to this article.
References
1.
Ackerman, B. A., and Hassler, W. T., Clean Coal, Dirty Air, Yale University Press, New Haven, Conn., 1981, p. 128.
2.
Blair, P. D., “Load Management Strategies for Electric Utilities: A Production Cost Simulation,” Simulation, Mar., 1979, pp. 93–102.
3.
Cadogan, J. B., A Dynamic Emissions Management System for Electric Utilities, dissertation presented to the University of Pennsylvania, at Philadelphia, Pa., in 1975, in partial fulfillment of the requirements for the degree of Doctor of Philosophy.
4.
Cadogan, J. B., and Eisenberg, L., “Sulfur Dioxide Emissions Management for Electric Power Systems,” Institute of Electric and Electronic Engineers Transactions on Power Apparatus and Systems, Pas‐96, Vol. 2, 1977, pp. 393–401.
5.
Coal Utilization in Pennsylvania's Electric Utilities: Assessment of Public Policy, Presented at Carnegie‐Mellon University, May 6, 1976, p. 205.
6.
Costle, D. M., “New Source Performance Standards for Coal‐fired Power Plans,” Journal of the Air Pollution Control Association, Vol. 29, No. 7, 1979, pp. 690–692.
7.
“EPA Announces Final NSPS for Coal‐fired Electric Power Plants,” New Focus, JAPCA, Vol. 29, No. 7, 1979, pp. 752–754.
8.
“Environmental Protection Agency New Source Performance Standards: Electric Utility Steam Generating Units,” Federal Register, Vol. 44, June, 1979, p. 113.
9.
Endrenyi, J., Reliability Modeling in Electric Power Systems, A Wiley Inter‐Science Publication, New York, N.Y., 1979, p. 338.
10.
Frank, H. H., An Evaluation of Minimum Emission Dispatch Algorithm, thesis presented to the University of Pennsylvania, at Philadelphia, Pa., in 1979, in partial fulfillment of the requirements for the degree of Master of Science.
11.
Gent, M. R., and Lamont, J. W., “Minimum Emission Dispatch,” Institute of Electric and Electronic Engineers Transactions, Pas‐90, 1971, pp. 2650–2660.
12.
El‐Hawary, M. E., and Christensen, G. S., Optimal Economic Operation of Electric Power Systems, Academic Press, New York, N.Y., 1979, p. 278.
13.
Monthly Energy Review, U.S. Dept. of Energy, Feb., 1981.
14.
de Nevers, N. H., Neligan, R. E., and Slater, H. H., “Air Quality Management, Pollution Control Strategies, Modeling and Evaluation,” Air Pollution, A. C. Stern, ed., Vol. V, 3rd ed., Academic Press, New York, N.Y., 1977, pp. 3–40.
15.
Particulate and Sulfur Dioxide Emission Control Costs for Large Coal‐fired Boilers, U.S. Environmental Protection Agency, Report by PEDCO Environmental, Inc., EPA‐450/3‐78‐007, 1978, p. 168.
16.
Study of Benefits of Improved Power Plant Reliability and Productivity, Phase I and II Reports, U.S. Dept. of Energy, Economic Regulatory Administration Division of Power Supply and Reliability, HCP/B60792, 1979, p. 215.
17.
Report of The World Coal Study: Coal—Bridge to the Future, Wilson, C. L., Report Director, Ballinger Publishing Company, Cambridge, Mass., 1980, p. 247.
18.
Synthetic Electric Utility Systems for Evaluating Advance Technologies, Power Technologies, Inc., Final Report to Electric Power Research Institute, EPRI EM‐285, Feb., 1977, p. 139.
19.
Tong, Ronnie Leung‐nee, Cost‐Effectiveness Evaluation of Electric Power Flue Gas Desulfurization Processes, thesis presented to the University of Pennsylvania, at Philadelphia, Pa., in 1981, in partial fulfillment of the requirements for the degree of Doctor of Philosophy.
20.
Vertis, A. S., Environmental Consideration in Power Dispatch, dissertation presented to the University of Pennsylvania, at Philadelphia, Pa., in 1973, in partial fulfillment of the requirements for the degree of Doctor of Philosophy.
21.
Zahavi, J., Economic‐Environmental Power Dispatch, dissertation presented to the University of Pennsylvania, in Philadelphia, Pa., in 1974, in partial fulfillment of the requirements for the degree of Doctor of Philosophy.
Information & Authors
Information
Published In
Copyright
Copyright © 1983 ASCE.
History
Published online: Mar 1, 1983
Published in print: Mar 1983
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.