Membrane/Oil Stripping of VOCs from Water in Hollow‐Fiber Contactor
Publication: Journal of Environmental Engineering
Volume 115, Issue 4
Abstract
Separation of volatile organic contaminants from water using a microporous hollow‐fiber membrane/oil stripping system is evaluated. Countercurrent flow of water and oil on opposite sides of an air‐filled gas‐permeable membrane is used to concentrate the contaminants in the oil phase. The rate of mass transfer under varying conditions is measured and compared to existing full‐ and laboratory‐scale air‐stripping processes, to membrane‐extraction processes, and to predictions based on known empirical and theoretical correlations. The correlations can be used as the basis for system design and scale‐up. This process incorporates the advantages of other membrane‐stripping processes, such as a high surface area to volume ratio for transfer, and independent control of the separate liquid phases. It also overcomes several disadvantages of extraction and stripping processes. There is no contact between the liquid phases and thus no potential for cross‐contamination or emulsion formation. The membrane separation of phases prevents flow channeling and flooding present in air‐stripping towers. Finally, materials used in this process may be recovered and recycled, preventing further environmental contamination.
Get full access to this article
View all available purchase options and get full access to this article.
References
1.
Amy, G. L., and Cooper, W. J. (1986). “Air stripping of volatile organic compounds using structured media.” J. Envir. Engrg., ASCE, 112(4), 729–743.
2.
Ball, W. P., et al. (1984). “Mass transfer of volatile organic compounds in packed tower aeration.” J. Water Pollution Control Assoc., 56(2), 127–136.
3.
Barbari, T. A., and King, C. J. (1982). “Equilibrium distribution coefficients for extraction of chlorinated hydrocarbons and aromatics into undecane.” Envir. Sci. and Tech., 16(9), 624–629.
4.
Brun, J.‐P., et al. (1985). “Sorption and pervaporation of dilute aqueous solutions of organic compounds through polymer membranes.” J. Membrane Sci., 25, 55–100.
5.
Clark, R. M., et al. (1984). “VOCs in drinking water: Cost of removal.” J. Envir. Engrg., ASCE, 10(6), 1146–1162.
6.
Cussler, E. L. (1984). Diffusion: Mass transfer in fluid systems. Cambridge Univ. Press, Cambridge, U.K.
7.
D'Elia, N. A., et al. (1986). “Liquid‐liquid extractions with microporous hollow fibers.” J. Membrane Sci., 29, 309–319.
8.
Dyksen, J. E., and Hess, A. F., III. (1982). “Alternatives for controlling organics in groundwater supplies.” J. Amer. Water Works Assoc., 74(8), 394–403.
9.
Graetz, L. (1883). “Uber die warmeleitungsfahigkelt von flussigkeiten.” Annalen der Physik und Chemie, 18, 79–94 (in German).
10.
Kavanaugh, M. C., and Trussell, R. R. (1980). “Design of aeration towers to strip volatile contaminants from drinking water.” J. Amer. Water Works Assoc., 72(12), 684–692.
11.
Kiani, A., et al. (1984). “Solvent extraction with immobilized interfaces in a microporous hydrophobic membrane.” J. Membrane Sci., 20, 125–145.
12.
Knudsen, J. G., and Katz, D. L. (1958). Fluid dynamics and heat transfer. McGraw‐Hill, New York, N.Y.
13.
Leveque, M. A. (1928). “Les lois de la transmission de chaleur par convection.” Annates des Mines, 13, 201–362 (in French).
14.
Munz, C., and Roberts, P. V. (1987). “Air‐water phase equilibria of volatile organic solutes.” J. Amer. Water Works Assoc., 79(5), 62–69.
15.
Nguyen, T. Q., and Nobe, K. (1987). “Extraction of organic contaminants in aqueous solutions by pervaporation.” J. Membrane Sci., 30, 11–22.
16.
Nirmalakhandan, N., et al. (1987). “Designing a cost efficient air stripping process.” J. Amer. Water Works Assoc., 79(1), 56–63.
17.
Norris, R. H., and Streid, D. D. (1940). “Laminar flow heat transfer coefficients for ducts.” Trans. Amer. Soc. of Mech. Engrs., 525–533.
18.
Prasad, R., and Sirkar, K. K. (1987). “Microporous membrane solvent extraction.” Separation Sci. and Tech., 22, 619–640.
19.
Prasad, R., et al. (1986). “Further studies on solvent extraction with immobilized interfaces in a microporous hydrophobic membrane.” J. Membrane Sci., 26, 79–97.
20.
Reid, R. C., et al. (1977). The properties of gases and liquids. McGraw‐Hill, New York, N.Y.
21.
Semmens, M., et al. (1989). “Volatile organics separation from water using a microporous hollow fiber membrane.” J. Amer. Water Works Assoc.
22.
Sieder, E. N., and Tate, G. E. (1936). “Heat transfer and pressure drop of liquids in tubes.” Industrial and Engrg. Chem., 28, 1429–1435.
23.
Westover, L. B., et al. (1974). “Novel mass spectrophotometric sampling device—Hollow fiber probe,” Anal. Chem., 46, 568–571.
24.
Yang, M.‐C., and Cussler, E. L. (1986). “Designing hollow fiber contractors.” Amer. Inst. of Civ. Engrs. J., 32(11), 1910–1916.
25.
Zhang, Q., and Cussler, E. L. (1985). “Hollow fiber gas membranes.” Amer. Inst. Chem. Engrs. J., 31(9), 1548–1553.
Information & Authors
Information
Published In
Copyright
Copyright © 1989 ASCE.
History
Published online: Aug 1, 1989
Published in print: Aug 1989
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.