Removal of Toxicity, COD, and Fe from a Metal-Working Facility UF Permeate
Publication: Journal of Hazardous, Toxic, and Radioactive Waste
Volume 18, Issue 1
Abstract
A metal-working facility employs two ultrafiltration (UF) membrane systems to treat spent metal working fluids and oily waste from sumps and other nonpoint sources. The facility is regulated for oil/grease, toxicity and Fe. Chemical-oxygen demand (COD) will be added in future permits. Also, the facility’s domestic wastewater treatment plant is aging, requiring replacement. Short-term treatment solutions were developed for toxicity and total Fe. A long-term approach for addressing Fe, toxicity, and COD and treatment of the facility’s domestic wastewater in a single bioprocess was also investigated. In the short term, granular activated carbon (GAC) columns were selected to remove toxicity and an aeration/pH adjustment/settling process was selected for Fe. Toxicity, COD, and Fe were removed successfully in a biological sequencing batch reactor (SBR) process, and a packaged conventional wastewater treatment plant will most likely be the chosen long-term solution. Depending on the discharge COD limit, an activated carbon polishing step may be needed prior to discharge.
Get full access to this article
View all available purchase options and get full access to this article.
References
Bashaar, A. Y. (2004). “Nutrients requirements in biological industrial wastewater treatment.” Afr. J. Biotechnol., 3(4), 236–238.
Melcer, H., et al. (2003). Methods for wastewater characterization in activated sludge modeling, Appendix D, Water Environment Research Foundation (WERF), Alexandria, VA.
Morgan, B., and Lahav, O. (2007). “The effect of pH on the kinetics of spontaneous Fe(II) oxidation by in aqueous solution—basic principles and a simple heuristic description.” Chemosphere, 68(11), 2080–2084.
Pan, S., Tay, J. H., He, Y. X., and Tay, S. L. (2004). “The effect of hydraulic retention time on the stability of aerobically grown microbial granules.” Lett. Appl. Microbiol., 38(2), 158–163.
Reed, B., Carriere, P., Lin, W., Roark, G., and Viadero, R. (1998). “Treatment of an aluminum manufacturer’s oily wastewater: Pilot-scale results and preliminary design.” ASCE Pract. Period. Hazard., Toxic, Radioact. Waste Manage., 2(3), 100–107.
Sherrard, R. M., Murray-Gulder, C. L., Rodgers, J. H., and Shay, Y. T. (2002). “Comparative toxicity of chlorothalonil and chlorpyrifos: Ceriodaphnia dubia and Pimephales promelas.” Environ. Toxicol., 17(6), 503–512.
Stumm, W., and Lee, G. F. (1961). “Oxygenation of ferrous iron.” Ind. Eng. Chem. Res., 53, 143–146.
U.S. Environmental Protection Agency (USEPA). (1991). “Technical support document for water quality-based toxics control.”, Office of Water, Washington, DC.
U.S. Environmental Protection Agency (USEPA). (2002). “Methods for measuring the acute toxicity of effluents and receiving waters to freshwater and marine organisms.”, Washington, DC.
Vance, D. B. (1994). “Iron: The environmental impact of a universal element.” National Environmental J., 4(3), 24–25.
Vaughan, R., Reed, B. E., Masciola, D. A., Malak, M., and Roark, G. W. (2001). “Operation of a full-scale ultrafiltration wastewater treatment system.” ASCE Pract. Period. Hazard., Toxic, Radioact. Waste Manage., 5(2), 98–110.
Water Analysis Handbook. (2008). 5th Ed., Hach Company, Loveland, CO.
Water Environment Federation (WEF). (2003). Methods for wastewater characterization in activated sludge modeling, Alexandria, VA.
Westall, J. C., Zachary, J. L., and Morel, F. M. M. (1976). “MINEQL: A computer program for the calculation of chemical equilibrium composition of aqueous systems.”, Ralph M. Parsons Laboratory, Dept. of Civil Engineering, Massachusetts Institute of Technology, Cambridge, MA.
Information & Authors
Information
Published In
Copyright
© 2014 American Society of Civil Engineers.
History
Received: Mar 8, 2012
Accepted: Dec 26, 2012
Published online: Dec 29, 2012
Discussion open until: May 29, 2013
Published in print: Jan 1, 2014
Authors
Metrics & Citations
Metrics
Citations
Download citation
If you have the appropriate software installed, you can download article citation data to the citation manager of your choice. Simply select your manager software from the list below and click Download.